FAS8000 Hybrid Flash Storage
Fast-track your business operations with scalable hybrid-flash storage.

Respond flexibly to changing business requirements.
- Accelerate SAN and NAS workloads with hybrid flash.
- Scale to 24 nodes with zero downtime to upgrade and service.
- Connect easily to the cloud.
Deliver uptime, security, and cost efficiency.
- Continuous Availability
- Proven Storage Efficiency with Built-in Encryption
- Simplified Management and Deep Application Integration

Leverage flexible, scalable hybrid-flash storage.
Designed for business-critical and consolidated environments that require:
- Rich data management.
- Enterprise-grade capabilities.
- Scalability for SAN and NAS workloads.
Primary Use Cases
Multiple Business Advantages
Scale flexibly with business growth.
Expand to 172PB. Cluster with AFF all-flash systems. Integrate existing third-party storage arrays.
Accelerate applications with flash.
Reduce latency and speed operations with Flash Cache™ and Flash Pool™.
Maximize uptime.
Eliminate planned downtime. Service and upgrade your systems during regular business hours.
Reduce risks.
Leverage integrated data protection and built-in encryption to meet your goals for business continuity and security.
Models & Specifications
![]() |
![]() |
![]() |
![]() |
|
---|---|---|---|---|
FAS8080 EX | FAS8060 | FAS8040 | FAS8020 | |
SCALE-OUT | ||||
NAS Scaling | 1–24 nodes (12 HA pairs) | |||
Maximum drives | 17,280 | 14,400 | 8,640 | 5,760 |
Maximum capacity | 172PB | 144PB | 86PB | 57PB |
Maximum Flash Pool™ capacity | 1728TB | 864TB | 576TB | 288TB |
Maximum memory | 3072GB | 1536GB | 768GB | 576GB |
SAN Scaling | 1–12 nodes (6 HA pairs) | |||
Maximum drives | 8,640 | 7200 | 4,320 | 2880 |
Maximum capacity | 86PB | 72PB | 43PB | 28PB |
Maximum Flash Pool capacity | 864TB | 432TB | 288TB | 144TB |
Maximum memory | 1536GB | 768GB | 384GB | 288GB |
Cluster interconnect | 2, 4, or 6 10GbE | 2 or 4 10GbE | 2 or 4 10GbE | 2 10GbE |
PER HA PAIR SPECIFICATIONS (ACTIVE-ACTIVE DUAL CONTROLLER) | ||||
Maximum capacity | 14400TB | 12000TB | 7200TB | 4800TB |
Maximum Flash Pool capacity | 144TB | 72TB | 48TB | 24TB |
Maximum drives | 1,440 | 1,200 | 720 | 480 |
Controller form factor | Dual enclosure HA;
2 controllers and 2 IOXMs in two 6U chassis; total of 12U |
Dual-enclosure HA; 2 controllers and 2 IOXMs in two 6U chassis; total of 12U or
Single-enclosure HA; 2 controllers in single 6U chassis |
Single-enclosure HA; 2 controllers in single 6U chassis | Single-enclosure HA;
2 controllers in single 3U chassis |
Memory | 256GB | 128GB | 64GB | 48GB |
Maximum Flash Cache™ | 24TB | 8TB | 4TB | 3TB |
Maximum Flash Pool | 144TB | 72TB | 48TB | 24TB |
Combined flash total | 144TB | 72TB | 48TB | 24TB |
NVRAM | 32GB | 16GB | 16GB | 8GB |
PCIe expansion slots | 24 | 8 or 24[1] | 8 | 4 |
Onboard I/O: UTA2
(10GbE/FCoE, 16Gb FC) |
8 | 8 | 8 | 4 |
Onboard I/O: 10GbE | 8 | 8 | 8 | 4 |
Onboard I/O: GbE | 8 | 8 | 8 | 4 |
Onboard I/O: 6Gb SAS | 8 | 8 | 8 | 4 |
Storage networking supported | FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB | |||
OS version | ONTAP® 8.2.2 RC1 or higher | ONTAP 8.2.1 RC2 or higher | ||
High-availability features | Alternate Control Path (ACP); Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optic | |||
Supported configurations
ONTAP 9, 8.3 |
Hardware cluster configurations:
|
|||
Disk shelves supported | DS212C (2U; 12 drives, 3.5” LFF, 12Gb)
DS224C (2U; 24 drives, 2.5" SFF, 12Gb) DS2246 (2U; 24 drives, 2.5" SFF, 6Gb) DS4246 (4U; 24 drives, 3.5" LFF, 6Gb) DS4486 (4U; 48 drives, 3.5" LFF, 6Gb) DS4243[2] (4U; 24 drives, 3.5" LFF) supported for upgrades only with ONTAP 9 DS4246 (DS4243 with IOM6 added) – supported in ONTAP 9.1+ DS14[2] disk shelves (mk2-AT, mk4) are supported for upgrades only, not supported in ONTAP 9+ See NetApp Disk Shelves and Storage Media for more details on each disk shelf and supported drive types. |
|||
Maximum RAID group sizes | RAID-TEC™ (triple parity, ONTAP 9)
|
|||
Operating systems supported | Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX® | |||
Max. number of LUNs | FAS8020/FAS8040: 8,192 (ONTAP 9 and 8.3.x)
FAS8060/FAS8080: 12,288 (ONTAP 9 and 8.3.x) 7-mode, all FAS8000 systems: 2048 |
|||
Number of supported SAN hosts | FAS8020/FAS8040: 4,096 (ONTAP 9 and 8.3.x)
FAS8060/FAS8080: 8,192 (ONTAP 9 and 8.3.x) 7-mode, all FAS8000 systems: Up to 512 hosts per HA pair |
|||
FlexVol® volumes | (In hardware clusters) Up to 1,000 per controller; (7-mode) up to 500 per controller | |||
Snapshot® copies | Up to 255,000 per controller
|
|||
Maximum volume size | 100TB | 100TB | 100TB | 70TB |
Maximum aggregate size | 400TB | 400TB | 324TB | 324TB |
Maximum Port Count (Includes Integrated Ports and PCIe Expansion Slots) | ||||
FC target ports (16Gb autoranging) | 64 | 64 | 24 | 12 |
FC target ports (4Gb or 8Gb) | 64 | 64 | 40 | 20 |
FCoE target ports, UTA (max.) | 32 | 32 | 24 | 12 |
10GbE ports (max.) | 64 | 64 | 32 | 16 |
GbE ports (max.) | 72 | 72 | 40 | 20 |
6Gb/12Gb SAS ports (max.) | 56 | 56 | 40 | 20 |
FC initiator ports (max.) | 72 | 72 | 40 | 20 |
Maximum Adapters | ||||
Dual 10GbE (optical or copper) | 16 | 16 | 8 | 4 |
Dual 10Gbase-T (RJ-45,CAT 6A-E) | 16 | 16 | 8 | 4 |
Quad GbE (copper) | 16 | 16 | 8 | 4 |
Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC) | 24 | 24 | 8 | 4 |
8Gb FC target | 16 | 16 | 8 | 4 |
Flash Cache Performance Acceleration Module (2TB) | 12 | 4 | 2 | 0 |
Flash Cache Performance Acceleration Module (1TB) | 24 | 8 | 4 | 2 |
Flash Cache Performance Acceleration Module (512GB) | 24 | 16 | 8 | 4 |
Quad 6Gb SAS storage HBA | 12 | 8 | 8 | 4 |
Quad 12Gb SAS storage HBA | 12 | 8 | 8 | 4 |
Quad 4Gb FC storage/tape HBA (fiber) | 16 | 8 | 8 | 4 |
SYSTEM ENVIRONMENTAL SPECIFICATIONS | ||||
Thermal Rating (at 200V) | 2,880 BTU (typical, per enclosure)
3,252 BTU (worst case, per enclosure) |
2,031 BTU (typical)
2,362 BTU (worst case) |
1,495 BTU (typical)
1,843 BTU (worst case) |
1,205 BTU (typical)
1,450 BTU (worst case) |
Weight (heaviest) | 115.08lb. | 121.47lb. | 119.49lb. | 74.08lb. |
Height | 12U (6U per enclosure) | 6U or 12U[1] | 6U | 3U |
Width | 19" IEC rack-compliant (17.6", 44.7cm) | |||
Depth | 24.3" (28.9" with cable management) | |||
Operating temperature, altitude, and relative humidity | 10°C to 40°C (50°F to 104°F); at <= 3,000m (at <= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature) | |||
Nonoperating temperature and relative humidity | –40°C to 70°C (–40°F to 158°F); 5% to 95% relative humidity, noncondensing, in original container | |||
Operating acoustic noise
|
FAS8020:
FAS8040/FAS8060:
FAS8080 EX:
|
|||
Compliance | RoHS-compliant | |||
Safety/emissions/immunity | Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
|||
NETAPP SYSTEMS CABINET | ||||
Rack space | 42U | |||
Dimensions (height/width/depth) | 78.75" (200cm)/23.6" (60cm)/44.3" (112.5cm) | |||
Minimum cabinet clearances for airflow | 10" (25.4cm) front and 12" (30.5cm) rear | |||
Minimum cabinet clearances for service | 30" (76.3cm) front and rear, 12" top | |||
AC power | 200 to 240VAC | |||
Current | 30A single-phase or 3-phase | |||
Weight (empty) | 307lb. (138kg) | |||
Features | Split rear door with cable egress opening, reversible front door (left or right handed) | |||
- Requires ONTAP 8.2.3 or higher.
- Not supported in ONTAP 9.
© 2018 NetApp, Inc. All rights reserved. No portions of this document may be reproduced without prior written consent of NetApp, Inc. Specifications are subject to change without notice. NetApp, the NetApp logo, ONTAP, Flash Cache, Flash Pool, FlexVol, MetroCluster, RAID DP, Snapshot, and SyncMirror are trademarks or registered trademarks of NetApp, Inc. in the United States and/or other countries. Windows and Windows Server are registered trademarks of Microsoft Corporation. Linux is a registered trademark of Linus Torvalds. Oracle is a registered trademark of Oracle Corporation. VMware and ESX are registered trademarks of VMware, Inc. Mac is a registered trademark of Apple Inc. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such.
Software
NetApp FAS8000 Series | |
---|---|
Features and Software Included with the ONTAP® Software |
Efficiency: FlexVol®, deduplication, compression, compaction[1], and thin provisioning Availability: MetroCluster™ and Multipath I/O Data protection: RAID-TEC™[1], RAID-DP®, and Snapshot® Performance: Storage quality of service (QoS) Scalable NAS container: FlexGroup Management: OnCommand® Unified Manager, OnCommand Performance Manager, OnCommand Workflow Automation, OnCommand API Services, OnCommand System Manager |
Extended Value Software (optional) |
A Premium Bundle is available for purchase with FAS8000 systems that includes:
|
- Available with ONTAP 9
See How Our Customers Are Using FAS Hybrid Flash Storage
How To Buy
Contact Us
- US: +1 877 263 8277
- Contact Sales
- Request Quote
Find A Partner
Different partner purchasing options are available, including:
NetApp OnDemand
Consume the storage your business requires with NetApp OnDemand consumption models.