Let's get started
+1-877-2NETAPP
(+1-877-263-8277)
  • Tag this page digg de.licio.us technorati reddit
V6000 Series Technical Specifications

View specifications for:
Product Highlights
Operating System NetApp Data ONTAP® 7G software
Operating Systems Supported Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac OS, VMware, ESX
Standard Software Features Snapshot™, Fast Boot, FlexVol™, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, FlexShare™, NDMP, antivirus, LDAP
Network Protocol Support NFS V2/V3/V4 over UDP or TCP, PC NFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts, WebDAV
SAN Protocol Support Fibre Channel Protocol (FCP), iSCSI; fabric-attached and direct-attached
Data Availability Software Clustered failover, SyncMirror™, MetroCluster
Data Protection Software SnapRestore®, SnapMirror®, SnapVault®, SnapLock® Enterprise, LockVault™ Enterprise
Data Management Software MultiStore®, SnapMover®, SnapDrive®, SnapManager® for Microsoft Exchange, SnapManager for Microsoft SQL Server, Single Mailbox Recovery, VFM® (Virtual File Manager), SnapValidator®, FlexClone™, FlexCache
Storage Management Software DataFabric® Manager, SecureAdmin™, ApplianceWatch™ for HP OpenView, ApplianceWatch for Tivoli, HiScan Agent for HDS HiCommand (applicable only to HDS arrays)
Hardware Features ROHS-compliant, full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote Management Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220 V version is available.
 
Active/Active Specifications V6080 V6070 V6040 V6030
Max. Raw Capacity 1,176TB 1008TB 840TB 840TB
Max. Number of Storage Array LUNs 1,176 1008 840 840
Storage Array
LUN Size
1TB 1TB 1TB 1TB
Max. Volume Size 16TB 16TB 16TB 16TB
ECC Memory 64GB 64GB 32GB 32GB
Nonvolatile Memory 4GB 4GB 1GB 1GB
Onboard Fibre Channel Ports 16(4Gb) 16(2Gb) 16(4Gb) 16(2Gb)
Onboard GbE Ports (copper) 12 12 12 12
PCI-X Expansion Slots
  PCI-X
  PCI-Express

6
10

6
10

6
10

6
10
Dual-Port FC Disk Adapters (max./min) 10 8 10 8
Optional Network Connectivity
Quad GbE TOE (copper) cards
Dual GbE (copper or fiber) cards
Single 10GbE TOE (fiber) cards
Dual iSCSI (copper or fiber) host adapter

10
10
4
6

4
10
4
6

10
10
4
6

4
10
4
6
Dual 4Gb or 2Gb FC Adapters  for Host Attach-SAN (max) 4 8 4 8
Dual FC, Single FC, or LVD SCSI Adapters for Tape (max) 6 6 6 6
 
Storage Subsystem Specifications
Storage Interface/Data Rate PCI-Based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4Gb/sec
Storage Arrays Hitachi TagmaStore Universal Storage Platform (USP)
Hitachi Lightning 9900V (9980V, 9970V)
Hitachi Lightning 9900 (9960, 9910)
Hitachi Thunder 9500V (9585V, 9580, 9570V, 9520V)
IBM TotalStorage Enterprise Storage Server (ESS) Model 800
  Turbo, 800, 750, F10, F20
IBM TotalStorage DS8100, DS8300, DS4800, DS4500, DS4400,
  DS4300 Turbo, DS4300, DS4100
HP StorageWorks XP Arrays (XP12000, XP1024, XP512,
  XP128, XP48)
EMC Clariion Networked Storage Systems
   CX-300, CX-500, CX-700, CX3-20, CX3-40, CX3-80
EMC Symmetrix Networked Storage Systems*
   DMX800, DMX1000, DMX2000, DMX3000, DMX3
Fujitsu ETERNUS Storage Systems
   ETERNUS 3000, ETERNUS 4000, ETERNUS 6000,
   ETERNUS 8000
3PAR InServ E200, S400, S800
 
Storage Array SAN Connectivity
Vendor Model
Brocade Silkworm 200E, 2800, 3014, 3016, 3200, 3250, 3800, 3850, 3900, 4012, 4020, 4100, 4900, 5000, 7500,12000, 24000, 48000
Cisco MDS 9020, 9120, 9124, 9140, 9216, 9216A, 9216i, 9506, 9509, 9513
McDATA Sphereon 4300, 4400, 4500, 4700
Intrepid 6064, 6140
Inrange CNT (Inrange) FC9000/64, FC9000/128, UMD
 
System Environmental
Specifications
V6040, V6080 (Single Controller Configuration) V6040, V6080 (Dual Controller Configuration)
AC Power/Max. Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 100 to 120VAC, 5.5A (typical)
200 to 240VAC, 2.9A (typical)
4.8A (max.) @ 100VAC
4.8A (max.) @ 200VAC
100 to 120VAC, 11.1A (typical)
200 to 240VAC, 5.8A (typical)
9.7A (max.) @ 100VAC
9.6A (max.) @ 200VAC
Thermal Rating 1867 Btu/hr, 574W (typical) 3734 Btu/hr, 1094W (typical)
Dimensions
  Weight
  Height

121 lb (54.8 kg)
10.3" (26.2 cm),
fits into 6U space

242 lb (109.6 kg)
20.8" (52.8 cm),
Fits into 12U space
  Width
  Depth
19" IEC rack-compliant (17.53", 44.53 cm)
23.5" (59.7 cm), 29.05" (73.8 cm) with cable management bracket
Operating Temperature & Relative Humidity 10º C to 40º C (50º F to 104º F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, non-condensing (28º C wet bulb temperature)
Nonoperating Temperature & Relative Humidity -40º C to 65º C (-40º F to 149º F); 10% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise 56.5 dBA sound pressure (LpA) @ normal operating conditions (at 22ºC and at sea level)
Min. Cabinet Clearances 1.85" (4.7 cm) for bezel, 3" (7.6 cm) for cable radius
Min. Service Clearances 25" (63.5 cm) from front of cabinet; 40" (76 cm) from rear of cabinet
 
System Environmental
Specifications
V6030, V6070 (Single Controller Configuration) V6030, V6070 (Dual Controller Configuration)
AC Power/Max. Current 100 to 240VAC, 11 to 5A (typical)/
12A (max.) @ 100VAC
100 to 240VAC, 22 to 10A (typical)/
24A (max.) at 100VAC
Thermal Rating 3,071 Btu/hr 6,142 Btu/hr
Dimensions
  Weight
  Height

121 lb (55 kg)
10.3" (26.2 cm)
Fits into 6U space

242 lb (110 kg)
20.8" (52.8 cm)
Fits into 12U space
  Width
  Depth
19" IEC rack-compliant (17", 43.2 cm)
23.5" (59.7 cm) without cable management bracket; 29.05" (73.8 cm) with cable management bracket
Operating Temperature & Relative Humidity 10°C to 40°C (50°F to 104°F) <2,100 m (<7,000') elevation;
10°C to 35°C (50°F to 95°F) <3,000 m (<10,000') elevation;
20% to 80% relative humidity, noncondensing
Nonoperating Temperature & Relative Humidity -20°C to 65°C (-4°F to 149°F); 8% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise 56.5 dBA sound pressure (LpA) at normal operating conditions (at 22°C and at sea level)
Min. Cabinet Clearances 1.85" (4.7 cm) for bezel; 3" (7.6 cm) for cable radius
Min. Service Clearances 25" (63.5 cm) front; 30" (76 cm) rear
 
Regulations
Filer Safety EN 60950:2000, CE, CSA 60950-00, NRTL (UL60950-2000), CB IEC 60950 Ed. 3 (all national deviations), EN60825-1:1994+A11
Disk Shelf Safety UL/C-UL; CE
Emissions FCC Class A, EN 55022:1998, EN 61000-3-2, EN 61000-3-3, CE, BSMI, AS/NZ 3548, VCCI
Immunity EN 55024:1998
 
V-Series TapeSAN Solutions
Model Backup Solutions
V30XX Direct-attached or SAN-attached(1), (2)
Supported tape drives Tape drive interface: LVD FC, LVD SCSI, FC, SE SCSI(3)
1 V-Series FC Tape SAN backup solution: www.netapp.com/osn/info/config.html.
2 V-Series GBE Tape SAN backup solution: www.netapp.com/osn/info/config_gbe.html.
3 FC = Fibre Channel; LVD = Low Voltage Differential; SE = Single-Ended; SE and LVD cannot be mixed on an adapter.