Technical Highlights
Maximum RAID Group Sizes RAID-DP® (high performance RAID 6)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 16 (14 data disks plus 2 parity disks)

RAID 41
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)

RAID 0 (striping over third-party Array LUNs)2

SyncMirror® (high resiliency RAID 1)
Options:
  1. RAID-DP + RAID 1
  2. RAID 4 + RAID 1
SAN Protocol Support Fibre Channel Protocol (FCP) for SCSI (4/2Gb); fabric-attached and direct-attached; IP SAN(iSCSI), Fibre Channel over Ethernet (FCoE)
File Service Protocol Support NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS
Other Protocol Support HTTP 1.0, HTTP 1.1 virtual hosts
LUNs Up to 2,048 server host LUNs
FlexVol® Volumes Up to 500 per controller
Volume/Aggregate Size 3 16TB
Snapshot™ Copies Up to 127,000
Number of Supported SAN Hosts Up to 12 ports4 per controller configured as front-end (host) connectivity ports
Up to 12 directly connected servers5 (per controller and per active-active configuration)
Up to 256 SAN connected servers (per controller and per active-active configuration)
Supported Configurations Highly Available Controller Configurations
Active-active controller with controller failover6, active-active controller with stretch (non switch) MetroCluster, active-active controller with fabric-attached MetroCluster
Highly Available Back-End (Disk) Configurations
Dual-path, multipath HA storage
Reliability Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports
Management Onboard serial console, diagnostic LED, full-duplex 10/100Base-T Ethernet remote LAN management port with RLM and onboard management interfaces, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts
Security Virus Protection
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role-Based Access Control (RBAC)
Disk Shelves Supported (Fibre Channel, SATA) and Configurations DS14mk2 FC, DS14mk4 FC, DS14mk2AT
DS4243, Dual-path,MPHA (MultiPath High Availability)
Disk Drive Capacities Supported FC—91/181/361/721/144/300/450GB, 600GB
SATA—2501GB, 3201GB, 500GB, 750GB, 1TB, 2TB
SAS - 300GB, 450GB, 600GB


Scalability V3170 V3160 V3140
  Active-Active
Configuration
Single Controller Active-Active
Configuration
Single Controller Active-Active
Configuration
Single Controller
Maximum Number of Disk Drives6 840 840 672 672 420 420
V-Series Array LUNs7 840 840 672 672 420 420
Maximum Drives per Back-End (Disk) FC Loop 84 84 84 84 84 84
Memory (ECC) 32GB 16GB 16GB 8GB 8GB 4GB
Non volatile Memory 4GB 2GB 4GB 2GB 1GB 512MB


Onboard I/O Ports/Slots V3170 V3160 V3140
  Active-Active
Configuration
Single Controller Active-Active
Configuration
Single Controller Active-Active
Configuration
Single Controller
Fibre Channel Ports
(target or initiator)
8 ports
1, 2, or 4Gb
(auto-sensing)
4 ports
1, 2, or 4Gb
(auto-sensing)
8 ports
1, 2, or 4Gb
(auto-sensing)
4 ports
1, 2, or 4Gb
(auto-sensing)
8 ports
1, 2, or 4Gb
(auto-sensing)
4 ports
1, 2, or 4Gb
(auto-sensing)
GbE Ports 4 2 4 2 4 2
I/O Expansion Slots 8 4 8 4 8 4


I/OCardSupport V3170 V3160 V3140
  Active-Active
Configuration
Single Controller Active-Active
Configuration
Single Controller Active-Active
Configuration
Single Controller
2-Port FC Disk Adapters (max.) 8 4 8 4 8 4
2-Port 4Gb FC Target Adapters (max.) 4 2 4 2 4 2
4-Port 4Gb FC Disk/Tape HBAs (max.) 8 4 8 4 8 4
4-Port 4Gb FC Target Adapter (max.) 8 6 3 6 3 6 3
2-Port Ultra320 SCSI Tape HBA 8 4 8 4 8 4
Optional Network/SAN Cards (max.)
2-Port FC Tape Adapters
4-Port 1GbE (copper) Cards
4-Port 1GbE TOE (copper) Cards
2-Port 10GbE TOE (fiber) Cards
2-Port 1GbE (copper or fiber) Cards
2-Port 1Gb iSCSI (copper or fiber) HBA

8
8
8
8
8
8

4
4
4
4
4
4

8
8
8
8
8
8

4
4
4
4
4
4

8
8
8
8
8
8

4
4
4
4
4
4
Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)9 8 4 8 4 8 4
Performance Acceleration Module
(max cards)
8 4 8 4 4 2
256GB Flash Cache1
(max cards)
4 2 2 1
512GB Flash Cache1
(max cards)
4 2

1Requires Data ONTAP 7.3.2 or later, 8.0.1 or later

Storage Arrays Supported by V3100 10
Storage Interface/Data Rate PCI-Based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4Gb/sec
Storage Arrays

IBM
Enterprise Storage Server (ESS), DS 4000 storage

HDS
USP Platform, AMS, Lightning Series, Thunder Series, SANRISE Series (Japan Only)

HP
StorageWorks XP Arrays, StorageWorks Enterprise Virtual Arrays

EMC
Symmetrix, Clariion

Fujitsu
ETERNUS Platform

3PAR
InServ Family

SUN
StorageTek



SAN Switch Connectivity with Storage Arrays Attached to a V3100
Vendor Model
Brocade Silkworm 48000, 24000, 12000, 7500, 5000, 4900 4100, 4020, 4012, 3900,3850, 3800, 3250, 3200, 3016, 3014, 2800, 200E
Cisco MDS 9513, 9509, 9506, 9216, 9216A, 9216i, 9140, 9124, 9120, 9020
McDATA Sphereon 4700, 4500, 4400, 4300
Intrepid 6140, 6064


Software
Operating System NetApp Data ONTAP
Host Operating Systems Supported Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware®, ESX
Software Features

Standard

RAID manager, including RAID-DP
Snapshot
Fast Boot
NIS
DNS
FilerView®
FlexVol
FlexShare
Deduplication
Network Data Management Protocol (NDMP)
Maintenance Center

























Licensed 11

FlexClone®
FlexCache
MultiStore®
SyncMirror

Protection Software
SnapMirror®
SnapRestore®
SnapVault®
Open Systems SnapVault
SnapLock® Compliance
SnapLock Enterprise
MetroCluster

Management Software
SnapManager® for Microsoft Exchange
SnapManager for Microsoft SQL Server™
SnapManager for Oracle
SnapManager for Microsoft SharePoint® Server
SnapManager for SAP®
SnapManager for Virtual Infrastructure
SnapValidator for Oracle
ApplianceWatch
SnapDrive® for UNIX®
SnapDrive for Windows

Protection Manager
CommandCentral™ Storage
File Storage Resource Manager
Operations Manager
Provisioning Manager
Single Mailbox Recovery  


Disk Drive Storage Expansion Shelf Specifications
Storage Expansion Shelves Supported
(Fibre Channel, SATA)
FC:          DS14mk4 FC
               DS14mk2 FC
SATA:    DS14mk2 AT
All shelves have 14 bays for 3.5" low-profile FC or SATA disk drives
Storage Expansion Shelf to Controller Interface Fibre Channel-Arbitrated Loop (FC-AL)
Storage Expansion Shelf Configurations New System Configurations
FC:          DS14mk4 FC with ESH4 (Embedded Switched Hub 4) Electronics
SATA:     DS14mk2 AT with AT-FCX Electronics
Supported via Upgrade Migrations from Installed Systems
FC:          DS14mk4 FC with ESH4 Electronics
               DS14mk2 FC with ESH4 or ESH2 Electronics
SATA:     DS14mk2 AT with AT-FCX Electronics
Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies9
AC Power/Maximum Current10 SATA:     7200 RPM drives: 3.01/1.51/7.4A @ 100VAC/200VAC/-40VDC
FC:         10,000 RPM drives: 3.09/1.56/7.61A @ 100VAC/200VAC/-40VDC
FC:         15,000 RPM drives: 3.96/1.94/10.22ª @ 100VAC/200VAC/-40VDC
Thermal Rating11 SATA:     7200 RPM drives: 1017 BTU/hr
FC:        10,000 RPM drives: 1043 BTU//hr
FC:        15,000 RPM drives: 1394 BTU/hr
Operating Acoustic Noise 49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Dimensions (height/width/depth) 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight 77 lb (35 kg) fully loaded


FC Switch Support—Tape/SAN
Vendor Model
Brocade Silkworm 2400/2800 (TapeSAN only)
Brocade Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000
McData ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
Qlogic 5600/5602
Cisco MDS 9120/9140/9216/9506/9509/9513/9124


NetApp Systems Cabinet
20A and 30A single-phase cabinets

20A Cabinet: Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors

30A Cabinet: Includes 4 power cords with NEMA L6-30P or IEC 309

20A Cabinet: 1 FAS3100 chassis & 12 DS14-type shelves



30A Cabinet: 1 FAS3100 chassis & 12 DS-14 type shelves
AC Power 200 to 240VAC
Current 20A Cabinet: Maximum 32A total
30A Cabinet: Maximum 24A total
Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances 48" (122 cm) front and rear
Shipping Height 90.6" (230 cm)
Weight (empty) 275 lb (125 kg)


V3100 Controller and System
Specifications
Active-Active
Configuration
Single Controller
Configuration
Controller Weight 122 lb (55.3 kg) 95 lb (43.1 kg)
Controller Height 10.2" (26 cm), fits into 6U space 10.24" (26 cm), fits into 6U space
Controller Width 19" IEC rack-compliant (17.6", 44.7 cm)
Controller Depth 24.3" (61.7 cm), 28" (71.1 cm) with cable management bracket
Operating Temperature, Altitude, and Relative Humidity 10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000' feet) elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature)
Non operating Temperature and Relative Humidity -40° C to 70° C (-40° F to 158° F); 5% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise = 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Min. Cabinet Clearances for Airflow 10" (25.4 cm) in front, 12" (30.5 cm) in rear
Min. Cabinet Clearances for Service 30" (76.2 cm ) in front, 30" (76.2 cm) in rear
Compliance RoHS-compliant
Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, BCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3


V3100 System Power Specifications
Model Input Voltage   Active/Active Single Controller
Typical Maximum Typical Maximum
One
Side
Both
Sides
One
Side
Both
Sides
V3140 100-120VAC Current, A 2.99 5.97 7.38 1.89 3.77 3.98
Power, W 297 594 736 187 373 396
Thermal, BTU/hr 1013 2026 2509 636 1272 1350
200-240VAC Current, A 1.49 2.98 3.6 0.97 1.93 1.97
Power, W 291 581 712 183 366 385
Thermal,
BTU/hr
991 1981 2427 625 1249 1313
V3160 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07
Power, W 405 810 969 235 470 505
Thermal, BTU/hr 1381 2761 3305 801 1602 1722
200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52
Power, W 394 788 930 230 459 493
Thermal,
BTU/hr
1343 2686 3170 782 1564 1680
V3170 100-120VAC Current, A 4.07 8.14 9.74 2.37 4.74 5.07
Power, W 405 810 969 235 470 505
Thermal,
BTU/hr
1381 2761 3305 801 1602 1722
200-240VAC Current, A 2.02 4.03 4.69 1.19 2.38 2.52
Power, W 394 788 930 230 459 493
Thermal,
BTU/hr
1343 2686 3170 782 1564 1680

1    RAID-DP is not supported with 3rd party Arrays. RAID_DP is the recommended configuration for drives greater than 144GB.
2   Maximum volume/aggregate size is calculated using base 2 arithmetic (1TB = 240 bytes).
3   Requires Data ONTAP® 7.3.
4   Requires Data ONTAP® 7.3.
5   For more information about cluster configurations, refer to
     http://now.netapp.com/NOW/knowledge/docs/ontap/rel704   /html/filer/cluster/index.htm.
6   NetApp disks will be supported in V-Series with ONTAP 7.3. The Maximum limit includes both Disks and LUNs if combined      in the same system.
7   Requires Data ONTAP® 7.3.
8   See V-Series hardware compatibility matrix for latest hardware and SAN switch connectivity support:
     http://now.netapp.com/NOW/knowledge/docs/V-Series/supportmatrix/V-Series_SupportMatrix.pdf
.
9   For detailed disk shelf specifications, refer to
     http://now.netapp.com/NOW/knowledge/docs/hardware/NetApp/site/guide11.htm#1792411
.
10 These numbers represent a single supply on, with fans on high setting at 100V, 200V, -40V DC.
11 Thermal rating, like current, is based on drive type/speed. This value is relatively constant regardless of input voltage, so      only one value is required for each.