NetApp VTL System Software VTL OS v5.x with hardware compression (Note: VTL OS 6.x is no longer recommended for new deployments).
Standard Software Features Multiple virtual drives, multiple virtual libraries, built-in data mover for direct VTL-to-physical tape creation, Tape Smart Sizing, Shadow Tapes, and AutoSupport.
Hardware Features Dual-core processors, built-in hardware compression, 4 GB/s Fibre Channel ports onboard, full-duplex 10/100/1000 Base-T Ethernet management port, Compact Flash, redundant hot-plug cooling fans, redundant hot-plug power supplies, 19" rack-mount enclosure, optional 220V 42U 19" system cabinet.
RAID Protection VTL-RAID (single parity). For maximum data protection, all backups to the VTL should be copied to physical tape.
Hot Spares Drives User defined global hot spare drives.
Capacity Expansion Option DS14mk2 disk shelf with 1 TB SATA drives.
 
NetApp VTL Specifications 1 VTL300 VTL700 VTL1400 2
Guidelines for Maximum Weekly Ingest of Backup Data      
VTLOS 5.x, no tape creation 150 TB/wk 315 TB/wk 630 TB/wk
VTLOS 5.x, with tape creation 125 TB/wk 175 TB/wk 350 TB/wk
VTLOS 6.x with deduplication enabled 3 28 TB/wk 35 TB/wk 70 TB/wk
Peak Aggregate Write Throughput      
VTLOS 5.x (100% writes) 600 MB/s 1150 MB/s 2300 MB/s
VTLOS 5.x (concurrent read/write workload w/50% writes) 340 MB/s 650 MB/s 1300 MB/s
VTLOS 6.x (default settings, 100% writes) 3 300 MB/s 380 MB/s 760 MB/s
VTLOS 6.x (default settings, concurrent read/write workload) 3 170 MB/s 215 MB/s 430 MB/s
Peak Single Stream Write Throughput      
VTLOS 5.x 4 100 MB/s 100 MB/s 100 MB/s
VTLOS 6.x 3, 4 70 MB/s 70MB/s 70MB/s
Peak Aggregate Read Throughput      
VTLOS 5.x 450 TB 900 TB 1800 TB
VTLOS 6.x 3 variable variable variable
Maximum Raw Capacity 55 TB 275 TB 550 TB
Maximum Effective Capacity      
VTLOS 5.x with standard compression @ 2:1 90 TB 450 TB 900 TB
VTLOS 6.x with deduplication enabled 3 variable variable variable
Maximum Number of Virtual Tapes      
Displayable in GUI per virtual library 1000 1000 1000
Total per system 10,000 10,000 20,000
Maximum User Data Per Virtual Tape 4 2 TB 2 TB 2 TB
Maximum Number of Virtual Libraries 256 256 512
Maximum Number of Virtual Drives 1,500 1,500 1,500
Maximum Concurrent In-use Virtual Drives
VTLOS 5.x, no Tape Creation 5 90 90 180
VTLOS 5.x, with Tape Creation 5 45 45 90
VTLOS 6.x with deduplication enabled, no tape creation 3, 5 80 80 160
VTLOS 6.x with deduplication enabled with tape creation 3, 5 40 40 80
Notes
1 Specifications provided are based on lab testing of maximum configurations for compression cards, disk shelves and backend ports. Actual results for each customer environment will vary based upon a number of factors. Maximum performance and capacity are calculated using Base10 arithmetic (i.e. 1TB=1,000,000,000,000 Bytes) and data that compresses at a ratio of 2-to-1.
2 A VTL1400 is the equivalent of two, independent VTL700 systems.
3 VTL OS 6.x is a restricted access release and is no longer recommended for new deployments. Space savings from VTL deduplication will vary based on a number of factors and may not provide any benefits versus standard compression, depending upon the environment. Read performance for a system running VTL deduplication will also vary based upon a number variables.
4 Applies to VTL OS releases 5.6.2 and 6.0.3 and higher, only
5 Maximum in-use concurrent virtual drives equals the maximum number of simultaneous backup streams per system and can be affected by use case, configuration settings, and concurrent operations. Maximum values for the tape creation use cases assume that all virtual drives are cloning to physical tape drives concurrently.
Disclaimer
These specifications are based on internal testing and are not intended to reflect the actual results that can be achieved in any particular user’s environment. NetApp is not responsible for any incidental or consequential damages in connection with the furnishing, application, or use of this information. These specifications are subject to change without notice.
 
Controller Environmental Specifications NetApp VTL300, NetApp VTL700 NetApp VTL1400
AC Power/Current (line voltage for standalone systems depends on local power distribution; system cabinets are 200 to 240 VAC only) 100 to 240 VAC, 3.83 to 1.75A, 50/60Hz
200 to 240 VAC, 2.00 to 1.75 A, 50/60 Hz
100 to 240 VAC, 7.66 to 3.50 A, 50/60 Hz
Thermal Rating
Typical
Maximum
 
1233 Btu/hr
1365 Btu/hr
 
2466 Btu/hr
2730 Btu/hr
Weight 75 lb (34 kg)
Fully configured
150 lb (68 kg)
Fully configured
Height 5.12" (13 cm)
3U EIA
10.6" (26 cm)
6U EIA
Width 19" IEC rack-compliant (17.7", 44.9 cm)
Depth 24" (61 cm) without cable management tray
30" (76.2 cm) with cable management tray
Operating Temperature, Altitude, and Relative Humidity 10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature)
Non-operating Temperature and Relative Humidity -40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise = 54 dBA sound pressure (LpA) at normal operating conditions (at 22° C and at sea level)
Min. Cabinet Clearances for Airflow 10" (25.4 cm) in front, 12" (30.5 cm) in rear
Min. Service Clearances for Service 30" (76.2 cm) in front, 30" (76.2 cm) in rear
Altitude 10,000 ft maximum
 
Storage Subsystem Specifications
Disk Drive Storage Shelf DiskShelf14 family - DS14mk2AT; each w/14 low-profile slots for SATA disk drives
Disk Drive Storage Shelf Interface PCI-based Fibre Channel-Arbitrated Loop (FC-AL)
Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)
AC Power/Max. Current 100 to 120 VAC/3.95A; 200 to 240 VAC/1.9A
Operating Temperature and Relative Humidity 10° C to 40° C (50° F to 104° F); 10 % to 95 % relative humidity, noncondensing
Nonoperating Temperature and Relative Humidity -40° C to 65° C (-40° F to 149° F); 10% to 95 % relative humidity, noncondensing
Thermal Rating 1017 Btu/hr (fully loaded shelf)
Operating Acoustic Noise 49 dBA at 1m at 23° C
Dimensions (Height/Width/Depth) 3U EIA (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight 77 lb (35 kg) fully loaded
 
NetApp Systems Cabinet
20 A and 30 A Single Phase Cabinets

20 A Cabinet - Includes 4 Power Cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 Connectors

30 A Cabinet - Includes 2 Power Cords with NEMA L6-30 or IEC 309 connectors


20 A Cabinet - 1 controller and 13 DS14-type shelves; 2 controllers and 12 DS14-type shelves



30 A Cabinet - 1 controller and 12 DS14-type shelves; 2 controllers and  11 DS-14 type shelves
AC Power 200 to 240 VAC
Current 20 A Cabinet - mdash;Maximum 32 A total
30 A Cabinet - Maximum 24 A total
Dimensions (Height/Width/Depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances 48" (122 cm) front and rear
Shipping Height 90.6" (230 cm)
Weight (Empty) 275 lb (125 kg)
 
Regulations NetApp VTL, DiskShelf14
FAS Safety EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Disk Shelf Safety EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI
Immunity EN 55024