Skip navigation

NetApp.com

A new version of this product is available. Please see the FAS8200 page.

  • Scalability 138PB HIGH CAPACITY
  • Nondisruptive operations 0 INTERRUPTIONS
  • High performance 4M IOPS

Models & Technical Specifications

Choose from four models.

FAS8080 EX

FAS8060

FAS8040

FAS8020

Compare Specifications by Model
chevron-down SCALE OUT SPECIFICATIONS
NAS Scaling 1–24 nodes (12 HA pairs) 1–24 nodes (12 HA pairs) 1–24 nodes (12 HA pairs) 1–24 nodes (12 HA pairs)
Maximum drives 17,280 14,400 8,640 5,760
Maximum capacity 172PB 144PB 86PB 57PB
Maximum Flash Pool™ capacity 1728TB 864TB 576TB 288TB
Maximum memory 3072GB 1536GB 768GB 576GB
SAN Scaling 1–12 nodes (6 HA pairs) (same for all models)
Maximum drives 8,640 7,200 4,320 2,880
Maximum capacity 86PB 72PB 43PB 28PB
Maximum Flash Pool capacity 864TB 432TB 288TB 144TB
Maximum memory 1536GB 768GB 384GB 288GB
Cluster interconnect 2, 4, or 6 10GbE 2 or 4 10GbE 2 or 4 10GbE 2 10GbE
chevron-down PER HA PAIR SPECIFICATIONS (ACTIVE-ACTIVE DUAL CONTROLLER)
Maximum capacity 14400TB 12000TB 7200TB 4800TB
Maximum Flash Pool capacity 144TB 72TB 48TB 24TB
Maximum drives 1,440 1,200 720 480
Controller form factor Dual enclosure HA;
2 controllers and 2 IOXMs in two 6U chassis; total of 12U
Dual-enclosure HA; 2 controllers and 2 IOXMs in two 6U chassis; total of 12U or
Single-enclosure HA; 2 controllers in single 6U chassis
Single-enclosure HA; 2 controllers in single 6U chassis Single-enclosure HA;
2 controllers in single 3U chassis
Memory 256GB 128GB 64GB 48GB
Maximum Flash Cache™ 24TB 8TB 4TB 3TB
Maximum Flash Pool 144TB 72TB 48TB 24TB
Combined flash total 144TB 72TB 48TB 24TB
NVRAM 32GB 16GB 16GB 8GB
PCIe expansion slots 24 8 or 24[1] 8 4
Onboard I/O: UTA2
(10GbE/FCoE, 16Gb FC)
8 8 8 4
Onboard I/O: 10GbE 8 8 8 4
Onboard I/O: GbE 8 8 8 4
Onboard I/O: 6Gb SAS 8 8 8 4
Storage networking supported FC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB
OS version ONTAP® 8.2.2 RC1 or higher ONTAP 8.2.1 RC2 or higher
High-availability features Alternate Control Path (ACP); Ethernet-based service processor and ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optic

Supported configurations




ONTAP 9, 8.3


Hardware cluster configurations:

  • Single-node cluster
  • Two-node switchless or switched cluster
  • Clusters of HA pairs

MetroCluster configurations for synchronous replication:

  • 2-node
  • 4-node: two x 2-node switched or switchless clusters with fabric-attached (switched) storage; 4 nodes total: a 2-node active-active cluster at each site)
  • 8-node (NAS-only): four x 2-node switched or switchless clusters with fabric-attached (switched) storage; 8 nodes total: a 4-node cluster at each site)

Consult the Interoperability Matrix Tool for FAS8000 support on earlier versions of ONTAP software.

Disk shelves supported DS212C (2U; 12 drives, 3.5" LFF, 12Gb)
DS224C (2U; 24 drives, 2.5" SFF, 12Gb)
DS2246 (2U; 24 drives, 2.5" SFF, 6Gb)
DS4246 (4U; 24 drives, 3.5" LFF, 6Gb)
DS4486 (4U; 48 drives, 3.5" LFF, 6Gb)
DS4243[2] (4U; 24 drives, 3.5" LFF) supported for upgrades only with ONTAP 9
DS4246 (DS4243 with IOM6 added) – supported in ONTAP 9.1+
DS14[2] disk shelves (mk2-AT, mk4) are supported for upgrades only, not supported in ONTAP 9+
See NetApp Disk Shelves and Storage Media for more details on each disk shelf and supported drive types.
Maximum RAID group sizes RAID-TEC™ (triple parity, ONTAP 9)
  • SSDs and Performance HDDs: 29 (26 data disks plus 3 parity disks)
  • Capacity HDDs: 21 (18 data disks plus 3 parity disks)
RAID 6 (RAID-DP®)
  • SSDs and Performance HDDs: 28 (26 data disks plus 2 parity disks)
  • Capacity HDDs: 20 (18 data disks plus 2 parity disks)
RAID 4
  • SSDs and Performance HDDs: 14 (13 data disks plus 1 parity disk)
  • Capacity HDDs: 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror®)
Operating systems supported Windows® 2000, Windows Server® 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux®, Oracle® Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX®
Max. number of LUNs FAS8020/FAS8040: 8,192 (ONTAP 9 and 8.3.x)
FAS8060/FAS8080: 12,288 (ONTAP 9 and 8.3.x)
7-mode, all FAS8000 systems: 2048
Number of supported SAN hosts FAS8020/FAS8040: 4,096 (ONTAP 9 and 8.3.x)
FAS8060/FAS8080: 8,192 (ONTAP 9 and 8.3.x)
7-mode, all FAS8000 systems: Up to 512 hosts per HA pair
FlexVol® volumes (In hardware clusters) Up to 1,000 per controller; (7-mode) up to 500 per controller
Snapshot® copies Up to 255,000 per controller
Maximum volume size 100TB 100TB 100TB 70TB
Maximum aggregate size 400TB 400TB 324TB 324TB
Maximum Port Count (Includes Integrated Ports and PCIe Expansion Slots)
FC target ports (16Gb autoranging) 64 64 24 12
FC target ports (4Gb or 8Gb) 64 64 40 20
FCoE target ports, UTA (max.) 32 32 24 12
10GbE ports (max.) 64 64 32 16
GbE ports (max.) 72 72 40 20
6Gb/12Gb SAS ports (max.) 56 56 40 20
FC initiator ports (max.) 72 72 40 20
Maximum Adapters
Dual 10GbE (optical or copper) 16 16 8 4
Dual 10Gbase-T (RJ-45,CAT 6A-E) 16 16 8 4
Quad GbE (copper) 16 16 8 4
Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC) 24 24 8 4
8Gb FC target 16 16 8 4
Flash Cache Performance Acceleration Module (2TB) 12 4 2 0
Flash Cache Performance Acceleration Module (1TB) 24 8 4 2
Flash Cache Performance Acceleration Module (512GB) 24 16 8 4
Quad 6Gb SAS storage HBA 12 8 8 4
Quad 12Gb SAS storage HBA 12 8 8 4
Quad 4Gb FC storage/tape HBA (fiber) 16 8 8 4
Notes

[1] Requires ONTAP 8.2.3 or higher.

[2] Not supported in ONTAP 9.

chevron-down SYSTEM ENVIRONMENTAL SPECIFICATIONS
Thermal Rating (at 200V) 2,880 BTU (typical, per enclosure)
3,252 BTU (worst case, per enclosure)
2,031 BTU (typical)
2,362 BTU (worst case)
1,495 BTU (typical)
1,843 BTU (worst case)
1,205 BTU (typical)
1,450 BTU (worst case)
Weight (heaviest) 115.08lb 121.47lb 119.49lb 74.08lb
Height 12U (6U per enclosure) 6U or 12U[1] 6U 3U
Width 19" IEC rack-compliant (17.6", 44.7cm)
Depth 24.3" (28.9" with cable management)
Operating temperature, altitude, and relative humidity 10°C to 40°C (50°F to 104°F); at <= 3,000m (at <= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28°C wet bulb temperature)
Nonoperating temperature and relative humidity –40°C to 70°C (–40°F to 158°F); 5% to 95% relative humidity, noncondensing, in original container
Operating acoustic noise FAS8020:
  • Declared sound power (LwAd) per ISO 9296: 7.8 Bel
  • Sound pressure (LpAm) (bystander positions): 62.6 dB

FAS8040/FAS8060:
  • Declared sound power (LwAd) per ISO 9296: 7.6 Bel
  • Sound pressure (LpAm) (bystander positions): 62.4 dB

FAS8080 EX:
  • Declared sound power (LwAd) per ISO 9296: 7.5 Bel @ normal operating conditions (at 23°C and at sea level)
Compliance RoHS-compliant (PDF)
Safety/ Emissions/ Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa)

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI
chevron-down NETAPP SYSTEMS CABINET
Rack space 42U
Dimensions (height/width/depth) 78.75" (200cm)/23.6" (60cm)/44.3" (112.5cm)
Minimum cabinet clearances for airflow 10" (25.4cm) front and 12" (30.5cm) rear
Minimum cabinet clearances for service 30" (76.3cm) front and rear, 12" top
AC power 200 to 240VAC
Current 30A single-phase or 3-phase
Weight (empty) 307lb. (138kg)
Features Split rear door with cable egress opening, reversible front door (left or right handed)
Request Quote

Software

Data Protocols

All supported data protocol licenses included.

How To Buy

Contact Us

US: +1 877 263 8277
Outside the US? Find Your Country

Request Quote

Find a Partner

Different partner purchasing options are available, including:

Financing Options

NetApp Capital Solutions offers innovative financing options for purchasing NetApp hardware, software and services.