| Maximum System Capacity |
4,320TB |
4,320TB |
3,600TB |
| Maximum Raw Capacity |
2,880TB |
2,880TB |
2,400TB |
| Maximum Drives |
1,440 |
1,440 |
1,200 |
| Controller Form Factor |
Dual enclosure HA;
2 controllers in two 6U chassis,
total of 12U |
Dual enclosure HA;
2 controllers in two 6U chassis,
total of 12U |
Single enclosure HA;
2 controllers in single 6U chassis |
| Memory |
192GB[1] |
96GB |
48GB |
| Flash Cache |
16TB maximum 1TB standard in base systems |
6TB maximum 1TB standard in base systems |
3TB maximum |
| PCIe Expansion Slots |
24 |
24 |
8 |
| Onboard I/O: 10GbE |
8 |
8 |
8 |
| Onboard I/O: 8Gb FC |
8–32 |
8–32 |
8–16 |
| Onboard I/O: 6Gb SAS |
0–24 |
0–24 |
0–8 |
| Storage Networking Supported |
FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP |
| OS Version |
Data ONTAP 8 |
| High-Availability Features |
Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optics |
| [1] 192GB of physical memory; actual memory allocated depends on the Data ONTAP release in use. |
| Supported Configurations |
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA620 |
| Disk Shelves Supported |
DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB/3TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB) |
| Maximum RAID Group Sizes |
RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk),
SATA: 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror) |
| Operating Systems Supported |
Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX |
| Max. Number of LUNs |
4,096 |
| Number of Supported SAN Hosts |
Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair |
| FlexVol Volumes |
Up to 500 per controller |
| Snapshot Copies |
Up to 127,000 |
| Maximum Volume/ Aggregate Size |
100TB |
100TB |
70TB |
| Maximum port count includes integrated ports and PCIe expansion slots |
| FC Target Ports (8Gb/4Gb) (max.) |
48/48 |
48/48 |
32/48 |
| FCoE Target Ports, UTA (max.) |
40[2] |
40[2] |
32 |
| 10GbE Ports (max.) |
40 |
40 |
24 |
| GbE Ports (max.) |
44[2] |
44[2] |
36 |
| 6Gb SAS Ports (max.) |
72 |
72 |
40 |
| FC Initiator Ports (max.) |
128 |
128 |
48 |
| Maximum Adapters |
| Dual 10GbE (optical or copper) |
16 |
16 |
8 |
| Quad GbE (copper) |
10[2] |
10[2] |
8 |
| Dual 10GbE FCoE SAN Unified Target Adapter (optical or copper) |
20[2] |
20[2] |
8 |
| 8Gb FC Target |
24 |
24 |
8 |
| Dual 8Gb VI for SnapMirror over Fibre Channel (SMoFC) |
8 |
8 |
6 |
| Flash Cache Performance Acceleration Module (1TB) |
16 |
6 |
2[3] |
| Flash Cache Performance Acceleration Module (512GB) |
16 |
12 |
6 |
| Quad 6Gb SAS Storage HBA |
12 |
12 |
8 |
| Quad 4Gb FC Storage/Tape HBA (fiber) |
24/16 |
24/16 |
8/8 |
| Dual SCSI Tape HBA |
16 |
16 |
8 |
| [2] Maximum number of Ethernet ports on all network adapter cards depends on the Data ONTAP release in use |
| [3] The FAS/V6210 can be configured with two 1TB modules plus two 512GB modules in an active-active dual controller configuration (one 1TB module plus one 512GB module per controller). This equals the maximum of 3TB per dual-controller high-availability system (1.5TB per controller). |
| Thermal Rating |
4,540 BTU (typical)
6,486 BTU (worst case) |
4,268 BTU (typical)
6,280 BTU (worst case) |
2,594 BTU (typical)
3,174 BTU (worst case) |
| Weight |
246 lb |
246 lb |
128 lb |
| Height |
20.4” (52 cm), fits into 12U space |
20.4” (52 cm), fits into 12U space |
10.2” (26 cm), fits into 6U space |
| Width |
19" IEC rack-compliant (17.6”, 44.7 cm) |
| Depth |
24.3” (28.9” with cable management) |
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature) |
| Nonoperating Temperature and Relative Humidity |
-40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container |
| Operating Acoustic Noise |
≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Compliance |
RoHS-compliant |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
| Rack Space |
42U |
| Dimensions (height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/44.3" (112.5 cm) |
| Minimum Cabinet Clearances for Airflow |
10" (25.4 cm) front and 12” (30.5 cm) rear |
| Minimum Cabinet Clearances for Service |
30” (76.3 cm) front and rear, 12” top |
| AC Power |
200 to 240VAC |
| Current |
30A Single Phase or 3-Phase |
| Weight (empty) |
307 lbs (138 kg) |
| Features |
Split rear door with cable egress opening, reversible front door (left or right handed), |