NetApp FAS6200 Series Technical Specifications
-
+1 877 263 8277
- Contact Sales
Technical specifications for the NetApp FAS6200 Series enterprise data storage systems.
See technical specifications that include the NetApp FAS6210, FAS6240, and FAS6280.
View specifications for:
All data in this table applies to active-active dual controller configurations.
| FAS6290 | FAS6250 | FAS6220 | |
| Maximum Raw Capacity | 5,760TB | 5,760TB | 4,800TB |
| Maximum Drives | 1,440 | 1,440 | 1,200 |
| Controller Form Factor | Dual enclosure HA;
2 controllers in two 6U chassis, total of 12U |
Dual enclosure HA;
2 controllers in two 6U chassis, total of 12U |
Single enclosure HA;
2 controllers in single 6U chassis |
| Memory | 192GB | 144GB | 96GB |
| Flash for Virtual Storage Tier | |||
| Maximum Flash Cache | 16TB | 6TB | 3TB |
| Maximum Flash Pool | 12TB | 12TB | 4TB |
| Combined Total | 16TB | 12TB | 4TB |
| PCIe Expansion Slots | 24 | 24 | 8 |
| Onboard I/O: 10GbE | 8 | 8 | 8 |
| Onboard I/O: 8Gb FC | 8–32 | 8–32 | 8–16 |
| Onboard I/O: 6Gb SAS | 0–24 | 0–24 | 0–8 |
| Storage Networking Supported | FC; FCoE; iSCSI; NFS; CIFS/SMB; HTTP; FTP | ||
| OS Version | Data ONTAP 8.1.2 GA or higher and Data ONTAP 8.0.5 | ||
| High-Availability Features | Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface; redundant hot-swappable controllers, cooling fans, power supplies, and optics |
||
| Supported Configurations | Highly available controller configurations
Active-active controller with controller failover and multipath HA storage Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™ V-Series Clusters of HA pairs (see clustered Data ONTAP support table) |
||
| Disk Shelves Supported | DS2246 (2U; 24 drives, 2.5" SFF)
DS4246 (4U; 24 drives, 3.5" LFF) DS4486 (4U; 48 drives, 3.5" LFF) DS4243 (4U; 24 drives, 3.5" LFF) DS14 disk shelves (mk2, mk2-AT, mk4) are supported for upgrades |
||
| Maximum RAID Group Sizes | RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks) SATA: 20 (18 data disks plus 2 parity disks) RAID 4 FC: 14 (13 data disks plus 1 parity disk), SATA: 7 (6 data disks plus 1 parity disk) RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror) |
||
| Operating Systems Supported | Windows 2000, Windows Server 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux®, Oracle Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX | ||
| Max. Number of LUNs | 4,096 | ||
| Number of Supported SAN Hosts | Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair |
||
| FlexVol Volumes | Up to 500 per controller | ||
| Snapshot Copies | Up to 127,000 | ||
| Maximum Volume/ Aggregate Size | 100TB | 100TB | 70TB |
| Maximum port count includes integrated ports and PCIe expansion slots | |||
| FC Target Ports (8Gb/4Gb) (max.) | 64/64 | 64/64 | 48/48 |
| FCoE Target Ports, UTA (max.) | 40[2] | 40[2] | 32 |
| 10GbE Ports (max.) | 48 | 48 | 24 |
| GbE Ports (max.) | 68 | 68 | 36 |
| 6Gb SAS Ports (max.) | 72 | 72 | 40 |
| FC Initiator Ports (max.) | 128 | 128 | 48 |
| Maximum Adapters | |||
| Dual 10GbE (optical or copper) | 16 | 16 | 8 |
| Quad GbE (copper) | 10 | 10 | 8 |
| Dual 10GbE FCoE SAN Unified Target Adapter (optical or copper) | 20 | 20 | 8 |
| 8Gb FC Target | 24 | 24 | 8 |
| Dual 8Gb VI for SnapMirror over Fibre Channel (SMoFC) | 8 | 8 | 6 |
| Flash Cache Performance Acceleration Module (1TB) | 16 | 6 | 2 |
| Flash Cache Performance Acceleration Module (512GB) | 16 | 12 | 6 |
| Quad 6Gb SAS Storage HBA | 12 | 12 | 8 |
| Quad 4Gb FC Storage/Tape HBA (fiber) | 24/16 | 24/24 | 8/8 |
| Dual SCSI Tape HBA | 16 | 16 | 8 |
| [2] Maximum number of Ethernet ports on all network adapter cards depends on the Data ONTAP release in use | |||
| System Environmental Specifications | |||
| Thermal Rating | 4,540 BTU (typical)
6,486 BTU (worst case) |
4,268 BTU (typical)
6,280 BTU (worst case) |
2,594 BTU (typical)
3,174 BTU (worst case) |
| Weight | 246 lb | 246 lb | 128 lb |
| Height | 20.4" (52 cm), fits into 12U space | 20.4" (52 cm), fits into 12U space | 10.2" (26 cm), fits into 6U space |
| Width | 19" IEC rack-compliant (17.6", 44.7 cm) | ||
| Depth | 24.3" (28.9" with cable management) | ||
| Operating Temperature, Altitude, and Relative Humidity | 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature) | ||
| Nonoperating Temperature and Relative Humidity | -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container | ||
| Operating Acoustic Noise | ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) | ||
| Compliance | RoHS-compliant | ||
| Safety/Emissions/Immunity | Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
||
| FC and FCoE Switch Support |
| NetApp offers broad support for FC and FCoE switches. A list of switches available through NetApp can be found here. For the complete list of supported switches, please consult the interoperability matrix found on the NetApp support site. Login access is required. |
See technical specifications that include the NetApp FAS6210, FAS6240, and FAS6280.