|
Operating System
|
NetApp Data ONTAP® 7.2.4 or later software
|
|
Operating Systems Supported
|
Windows® 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware, ESX
|
|
Standard Software Features
|
Integrated automatic RAID manager, including RAID-DP™, Snapshot™, Fast Boot, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, FlexVol®, FlexShare™, SSH, Maintenance Center, Network Data Management Protocol (NDMP)
|
|
File Service and Other Protocol Support
|
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts
|
|
SAN Protocol Support
|
Fibre Channel Protocol (FCP) (8/4/2/1Gb); fabric-attached and direct-attached; IP SAN (iSCSI), Fibre Channel over Ethernet (FCoE)
|
|
Licensed Software Products
|
FlexClone ™, FlexCache , MultiStore ®, SnapMirror ®, SnapRestore ®, SnapDrive®, SnapManager ® for Microsoft Exchange, SnapManager for Microsoft SQL Server, SnapManager for Oracle®, Single Mailbox Recovery , SnapVault ®, SnapMover®, SnapLock ® Compliance, SnapLock Enterprise, SyncMirror ®, MetroCluster , CommandCentral™ Storage , Protection Manager
2 ,
File Storage Resource Manager , SAN Manager, Operations Manager
3 , ApplianceWatch™ for HP Openview, ApplianceWatch for Tivoli®
|
|
Standard Hardware Features
|
ROHS-compliant, full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220 V 42U 19" system cabinet
|
|
Maximum RAID Group Sizes
|
RAID 6 (RAID-DP) FC – 28 (26 data disks plus 2 parity disks), SATA – 16 (14 data disks plus 2 parity disks)
RAID 44 FC – 14 (13 data disks plus 1 parity disk), SATA – 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
|
| Supported Configurations |
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA600
|
|
Disk Shelves Supported (Fibre Channel, SATA) and Configurations
|
DS14, DS14mk2 FC, DS14mk4 FC, DS14mk2AT
Dual-path
DS4243, MPHA (MultiPath High Availability)
|
|
Disk Drive Capacities Supported
|
FC-91/181/361/721/300GB, 450GB, 600GB
SATA-500GB, 1TB, 2TB
SAS: 300GB, 450GB, 600GB
|
1 9/18/36/72GB drives are supported but not currently shipping.
2 Protection Manager was previously known as Business Continuance Option.
3 Operations Manager was previously known as DataFabric® Manager (DFM).
4 RAID 6 is the recommended configuration for drives greater than 144GB. |
|
| |
| |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
| Max. Raw Capacity
(5), (6) |
2,352TB
|
2,352TB
|
1680TB
|
1680TB
|
| Max. Number of Disk Drives |
1,176
|
1,176
|
840
|
840
|
| Max. Number of FC Loops (dual attach) |
14
|
14
|
10
|
10
|
| Max. Drives per FC Loop |
84 |
| Max. Volume/Aggregate Size |
16TB |
| Max. Number of LUNs per Controller |
2048 |
| ECC Memory |
64GB
|
32GB
|
32GB
|
16GB
|
| Nonvolatile Memory |
4GB
|
2GB
|
1GB
|
512MB
|
| Onboard GbE Ports |
12
|
6
|
12
|
6
|
| Onboard 4Gb FC Ports (target or initiator)7 |
16
|
8
|
16
|
8
|
5 Max. capacity is derived based on the type, size, and number of the drives.
6 Max. capacity is calculated using Base10 arithmetic (i.e., 1TB = 1,000,000,000,000 bytes).
7 Autosensing ports: 1, 2, 4Gb. |
|
| |
| |
Active/Active
Configuration |
Single
Controller |
Active/Active
Configuration |
Single
Controller |
| PCI Express Expansion Slots |
10 |
5 |
10 |
5 |
| PCI-X Expansion Slots |
6 |
3 |
6 |
3 |
| Optional Network Connectivity (max.) |
6 |
3 |
6 |
3 |
| Quad GbE TOE (copper) Cards |
10 |
5 |
10 |
5 |
| Quad GbE (copper) Cards |
10 |
5 |
10 |
5 |
| Single 10GbE TOE (fiber) 10GBASE-SR Cards |
4 |
2 |
4 |
2 |
| Dual 10GbE TOE (fiber) 10GBASE-SR Cards |
10 |
5 |
10 |
5 |
| Dual GbE (copper or fiber) Cards |
10 |
5 |
10 |
5 |
| Dual GbE (copper or fiber) Cards |
6 |
3 |
6 |
3 |
|
Dual 4Gb FC Initiator Adapters (max.)
|
10
|
5
|
10
|
5
|
|
Quad 4Gb FC Initiator Adapters (max.)
|
10
|
5
|
10
|
5
|
|
Dual 4Gb FC Target (SAN) Adapters (max.)
|
8
|
4
|
8
|
4
|
|
Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)1
|
8
|
4
|
8
|
4
|
|
Dual FC, LVD SCSI Tape Adapters (max.)
|
6
|
3
|
6
|
3
|
|
4port SAS HBA
|
|
|
|
|
|
Performance Acceleration Module (PAM)
|
10
|
5
|
8
|
4
|
|
512GB Flash Cache1
(max cards)
|
8
|
4
|
4
|
2
|
1 Requires Data ONTAP 7.3.2 or later, 8.0.1 or later
|
| |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) |
100 to 120VAC, 11.2A (typical)
200 to 240VAC, 5.8A (typical)
19.4A (max.) @ 100VAC
9.6A (max.) @ 200VAC |
100 to 120VAC, 5.6A (typical)
200 to 240VAC, 2.9A (typical)
9.7A (max.) @ 100VAC
4.8A (max.) @ 200VAC |
| Thermal Rating |
3740 Btu/hr, 1096W (typical) |
1870 Btu/hr, 548W (typical) |
| Weight |
242 lb (109.6 kg) |
121 lb (54.8 kg) |
| Height |
20.8" (52.8 cm), fits into 12U space |
10.3" (26.2 cm), fits into 6U space |
| Width |
19" IEC rack-compliant (17.53", 44.53 cm) |
| Depth |
23.5" (59.7 cm), 29.05" (73.8 cm) with cable management bracket |
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature) |
| Nonoperating Temperature and Relative Humidity |
-40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating Acoustic Noise |
56.5 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Min. Cabinet Clearances |
1.85" (4.7 cm) for bezel, 3" (7.6 cm) for cable radius |
| Min. Service Clearances |
25" (63.5 cm) from front of cabinet; 40" (76 cm) from rear of cabinet |
|
| |
| Disk Drive Storage Shelf |
DiskShelf14 family—DS14, DS14mk4 FC, and DS14mk2AT; each w/14 low-profile slots for FC and SATA disk drives |
| Disk Drive Storage Shelf Interface |
PCI-based Fibre Channel-Arbitrated Loop (FC-AL) |
| DiskShelf14 Interface |
Dual, redundant electronically switched hub (ESH4) modules or dual, redundant ATA modules |
| Power Supply/Cooling Fans |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V) |
| AC Power/Max. Current |
100 to 120VAC/4.52A; 200 to 240VAC/2.23A |
| Thermal Rating |
1,538 Btu/hr (fully loaded shelf) |
| Operating Acoustic Noise |
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Dimensions (height/width/depth) |
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
| Weight |
77 lb (35 kg) fully loaded |
|
| |
| Disk Drive Types and Capacities Supported |
SAS 15,000 RPM: 300GB, 450GB, 600GB
SATA 7,200 RPM: 500GB, 1TB, 2 TB
All shelves have 24 bays for 3.5” low-profile SAS or SATA disk drives |
| Disk Enclosure to Controller Interface |
Serial Attached SCSI (SAS) operating at 3Gb, requires PCIe SAS Host Bus Adapter card or available embedded SAS port |
| Disk Enclosure Configurations |
Dual IOM3 (Input/Output Module) Controller modules |
| Power Supply/Cooling Fans |
Dual (SATA) or quadruple (SAS), redundant, hot-pluggable, integrated power supply/fan assemblies |
| Operating Temperature Range |
41°F to 104°F - (5°C to 40°C) |
| Nonoperating Temperature Range |
34°F to 122°F - (1°C to 50°C) |
| Relative Humidity |
20 to 80% noncondensing |
| Operating Acoustic Noise |
6.6B LwA @ 20°C |
| Input power frequency, Hz (AC) |
50 to 60 |
| Dimensions (height/width/depth) |
4 EIA U (7”, 17.8 cm)/19” IEC rack-compliant (19”, 48.3 cm)/24” (61 cm) |
| Clearance Dimensions (front-cooling/rear-cooling and maintenance/front-maintenance) |
6” (15.3cm)/12” (30.5cm)/25” (55.9cm) |
| Weight |
110 lb (49.9 kg) fully loaded, 53.7 lbs (24.4 kb) without disk drives |
|
| |
| FC = Fibre Channel; LVD = Low Voltage Differential. |
|
| |
| Includes 2 Sets of Dual 16A, Zero U Power Distribution Units (PDUs) or
1 Set of 24A Zero U PDUs |
Accommodates 1 controller and 12 disk shelves or 2 controllers and 10 disk shelves or 14 disk shelves
1 controller and 10 disk shelves or 2 controllers and 6-8 disk shelves or 11-14 disk shelves only |
| AC Power |
200 to 240VAC |
| Current |
32A total-2 redundant sets of dual 16A cables with NEMA L6-20 or IEC 309 connectors or Australia AS/NZ53123-20; 24A total-2 redundant cables with NEMA L6-30 or IEC 309 connectors |
| Dimensions (height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
| Min. Clearances |
48" (122 cm) front and rear |
| Shipping Height |
90.6" (230 cm) |
| Weight (empty) |
275 lb (125 kg) |
|
| |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI |
|