| Maximum System Capacity |
2,880TB |
2,880TB |
1,800TB |
1,800TB |
720TB |
| Maximum Drives |
960 |
960 |
600 |
600 |
240 |
| Controller Form Factor |
Dual enclosure HA; 2 controllers in two 3U chassis, total of 6U |
Single enclosure HA; 2 controllers in single 3U chassis |
Dual enclosure HA; 2 controllers in two 3U chassis, total of 6U |
Single enclosure HA; 2 controllers in single 3U chassis |
Single enclosure HA; 2 controllers in single 3U chassis |
| Memory |
32GB |
32GB |
16GB |
16GB |
8GB |
| Maximum Flash Cache |
2TB |
2TB |
1TB |
1TB |
512GB |
| PCIe Expansion Slots |
12 |
4 |
12 |
4 |
4 |
| Onboard I/O: 4Gb FC |
4 |
4 |
4 |
4 |
4 |
| Onboard I/O: 6Gb SAS |
4 |
4 |
4 |
4 |
4 |
| Onboard I/O: GbE |
4 |
4 |
4 |
4 |
4 |
| Storage Networking Supported |
FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP |
| OS Version |
Data ONTAP® 7 and 8 |
| High-Availability Features |
Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface;
redundant hot-swappable controllers, cooling fans, power supplies, and optics |
| Supported Configurations |
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320 |
| Software Features |
Standard
One SAN or NAS protocol (iSCSI, FC, NFS, or CIFS)
RAID manager, including RAID-DP®
Snapshot™
FlexVol®
FlexShare®
Deduplication
Compression (check with sales representative for ordering instructions)
Thin provisioning
Disk sanitization
Operations Manager
Provisioning Manager
Protection Manager
Protection Manager DR
DFM Management Server (optional)
System Manager
FilerView®
MultiStore®
FlexCache™
Cluster failover
MetroCluster
SyncMirror®
Open Systems SnapVault
DSM/MPIO |
Optional
Extended Value software:
Additional SAN/NAS protocols (iSCSI, FC, NFS, CIFS)
SnapRestore®
SnapMirror®
SnapVault®
FlexClone®
SnapManager® Suite, includes:
NetApp Complete Bundle (includes all above Extended Value software)
Other software:
|
| Disk Shelves Supported |
DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB/3TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB) (Note: 3TB drive requires Data ONTAP 8; SSDs not currently supported with FAS3210)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB) |
| Maximum RAID Group Sizes |
RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)
RAID 4
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk) |
| Operating Systems Supported |
Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX |
| Maximum Number of LUNs |
4,096 |
| Number of Supported SAN Hosts |
Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair |
| FlexVol® Volumes |
Up to 500 per controller |
| Snapshot Copies |
Up to 127,000 |
| Maximum Volume/Aggregate Size |
70TB |
70TB |
50TB |
50TB |
50TB |
| Maximum port count includes integrated ports and PCIe expansion slots |
| FC Target (8Gb/4Gb) (max.) |
24/52 |
8/20 |
24/52 |
8/20 |
8/20 |
| 10GbE/FCoE Target Ports (max) |
24 |
8 |
24 |
8 |
8 |
| GbE (max.) |
52[1] |
20 |
52[1] |
20 |
20 |
| 6Gb SAS (max.) |
52 |
20 |
52 |
20 |
20 |
| FC Initiator (max.) |
52 |
20 |
52 |
20 |
20 |
| Maximum Adapters |
| Dual 10GbE (optical or copper) |
12 |
4 |
12 |
4 |
4 |
| Quad GbE (copper) |
12[1] |
4 |
12[1] |
4 |
4 |
| Dual 10GbE FCoE SAN Unified Target Adapter (optical or copper) |
12 |
4 |
12 |
4 |
4 |
| 8Gb FC Target (optical) |
12 |
4 |
12 |
4 |
4 |
| Dual 8Gb VI for SnapMirror® over Fibre Channel (SMoFC) |
2 |
2 |
2 |
2 |
2 |
| Flash Cache Performance Acceleration Module (1TB) |
2 |
2 |
N/A |
N/A |
N/A |
| Flash Cache Performance Acceleration Module (512GB) |
4 |
4 |
2 |
2 |
N/A |
| Flash Cache Performance Acceleration Module (256GB) |
N/A |
N/A |
4 |
4 |
2[2] |
| Quad 6Gb SAS Storage HBA |
12 |
4 |
12 |
4 |
4 |
| Quad 4Gb FC Storage/Tape HBA |
12 |
4 |
12 |
4 |
4 |
| Dual SCSI Tape HBA |
12 |
4 |
12 |
4 |
4 |
| Thermal Rating |
1,884 BTU (typical)
2,485 BTU (worst case) |
1,393 BTU (typical)
1,867 BTU (worst case) |
1,591 BTU (typical)
2,168 BTU (worst case) |
1,256 BTU (typical)
1,707 BTU (worst case) |
1,577 BTU (typical)
2,137 BTU (worst case) |
| Weight |
148 lb |
80 lb |
148 lb |
80 lb |
80 lb |
| Height |
10.2” (26 cm), fits into 6U space |
5.1” (13 cm), fits into 3U space |
10.2” (26 cm), fits into 6U space |
5.1” (13 cm), fits into 3U space |
5.1” (13 cm), fits into 3U space |
| Width |
19" IEC rack-compliant (17.6”, 44.7 cm) |
| Depth |
24” (26.5” w/cable management) |
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature) |
| Nonoperating Temperature and Relative Humidity |
-40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container |
| Operating Acoustic Noise |
≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Compliance |
RoHS-compliant |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI |