| Maximum RAID Group Sizes |
RAID-DP® (high performance RAID 6) FC: 28 (26 data disks plus 2 parity disks) SATA: 16 (14 data disks plus 2 parity disks)
RAID 41 FC: 14 (13 data disks plus 1 parity disk) SATA: 7 (6 data disks plus 1 parity disk)
SyncMirror® (high resiliency RAID 1) Options:
- RAID-DP + RAID 1
- RAID 4 + RAID 1
|
| SAN Protocol Support |
Fibre Channel Protocol (FCP) (8/4/2/1Gb); fabric-attached and direct-attached; IP SAN(iSCSI), Fibre Channel over Ethernet (FCoE) |
| File Service Protocol Support |
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS |
| Other Protocol Support |
HTTP 1.0, HTTP 1.1 virtual hosts |
| LUNs |
Up to 2,048 server host LUNs |
| FlexVol® Volumes |
Up to 500 per controller |
Volume/Aggregate Size2
|
16TB
|
Snapshot™ Copies
|
Up to 127,000
|
| Number of Supported SAN Hosts |
Up to 12 ports3 per controller configured as front-end (host) connectivity ports Up to 12 directly connected servers4 (per controller and per active-active configuration) Up to 256 SAN connected servers (per controller and per active-active configuration) |
Supported Configurations
|
Highly Available Controller Configurations Active-active controller with controller failover5, active-active controller with stretch (non switch) MetroCluster, active-active controller with fabric-attached MetroCluster Highly Available Back-End (Disk) Configurations Dual-path, multipath HA storage |
| Reliability |
Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports |
| Management |
Onboard serial console, diagnostic LED, full-duplex 10/100Base-T Ethernet remote LAN management port with RLM and onboard management interfaces, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts |
Security
|
Virus Protection Authentication: Kerberos (MIT/Active Directory) Authorization: LDAP, NIS Auditing: File access logging Encryption: IPSec, SSL, SSH, SMB signing Role-Based Access Control (RBAC) |
Disk Shelves Supported and Configurations
|
DS14, DS14mk2 FC, DS14mk4 FC, DS14mk2 AT Dual-path
DS4243, MPHA (MultiPath High Availability)
|
Disk Drive Capacities Supported
|
FC: 300GB, 450GB, 600GB
SATA: : 250GB, 500GB, 750GB, 1TB, 2TB
SAS: 300GB, 450GB, 600GB
|
|
| |
| |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
| Maximum Number of Disk Drives |
840 |
840 |
672 |
672 |
420 |
420 |
| Maximum Raw Capacity (TB) |
1680 |
1680 |
1344 |
1344 |
840 |
840 |
| Maximum Drives per Back-end (Disk) FC Loop |
84 |
84 |
84 |
84 |
84 |
84 |
| Memory (ECC) |
32GB
|
16GB
|
16GB
|
8GB
|
8GB
|
4GB |
| Non volatile Memory |
4GB |
2GB |
4GB |
2GB |
1GB |
512MB |
|
| |
| |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
Fibre Channel Ports (target or initiator) |
8 ports 1, 2, or 4Gb (auto-sensing)
|
4 ports 1, 2, or 4Gb (auto-sensing)
|
8 ports 1, 2, or 4Gb (auto-sensing)
|
4 ports 1, 2, or 4Gb (auto-sensing)
|
8 ports 1, 2, or 4Gb (auto-sensing)
|
4 ports 1, 2, or 4Gb (auto-sensing)
|
| GbE Ports |
4 |
2 |
4 |
2 |
4 |
2 |
| Expansion Slots |
8 |
4 |
8 |
4 |
8 |
4 |
|
| |
| |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
| 2-Port FC Disk Adapters (max.) |
8 |
4 |
8 |
4 |
8 |
4 |
| 2-Port 4Gb FC Target Adapters (max.) |
4 |
2 |
4 |
2 |
4 |
2 |
| 4-Port 4Gb FC Disk/Tape HBAs (max.) |
8 |
4 |
8 |
4 |
8 |
4 |
| 4-Port 4Gb FC Target Adapter (max6.) |
6 |
3 |
6 |
3 |
6 |
3 |
| 2-Port Ultra320 SCSI Tape HBA |
8 |
4 |
8 |
4 |
8 |
4 |
Optional Network/SAN Cards (max.) 2-Port FC Tape Adapters 4-Port 1GbE (copper) Cards 4-Port 1GbE TOE (copper) Cards 2-Port 10GbE TOE (fiber) Cards 2-Port 1GbE (copper or fiber) Cards 2-Port 1Gb iSCSI (copper or fiber) HBA |
8 8 8 8 8
8 |
4 4 4 4 4
4 |
8 8 8 8 8
8 |
4 4 4 4 4
4 |
8 8 8 8 8
8 |
4 4 4 4 4
4 |
| Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)1 |
8 |
4 |
8 |
4 |
8 |
4 |
| 4port SAS HBA |
8 |
4 |
8 |
4 |
8 |
4 |
Performance Acceleration Module (max cards) |
8 |
4 |
8 |
4 |
4 |
2 |
256GB Flash Cache1,2 (max cards) |
|
|
4 |
2 |
2 |
1 |
512GB Flash Cache1 (max cards) |
4 |
2 |
|
|
|
|
1Requires Data ONTAP 7.3.2 or later, 8.0.1 or later
2Flash Cache is not supported with Data ONTAP 8.1 running on the FAS/V3140 systems
|
| |
| Operating System |
NetApp Data ONTAP |
| Host Operating Systems Supported |
Windows® 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac OS, VMware, ESX |
| Software Features |
Standard
RAID manager, including RAID-DP Snapshot Fast Boot NIS DNS FilerView® FlexVol FlexShare™ Deduplication Network Data Management Protocol (NDMP) Maintenance Center |
Licensed7
FlexClone® FlexCache™ MultiStore® SyncMirror
Protection Software
SnapMirror® SnapRestore® SnapVault® Open Systems SnapVault SnapLock® Compliance SnapLock Enterprise MetroCluster
Management Software
SnapManager® for Microsoft Exchange SnapManager for Microsoft SQL Server™ SnapManager for Oracle SnapManager for Microsoft SharePoint® Server SnapManager for SAP® SnapManager for Virtual Infrastructure SnapValidator for Oracle ApplianceWatch™ SnapDrive® for UNIX® SnapDrive for Windows Protection Manager CommandCentral™ Storage File Storage Resource Manager Operations Manager Provisioning Manager Single Mailbox Recovery |
6 Requires Data ONTAP 7.3 7 For more information about available software, refer to http://www.netapp.com/products/software.html.
|
| |
Storage Expansion Shelves Supported (Fibre Channel, SATA)
|
FC: DDS14mk4 FC DS14mk2 FC SATA: DS14mk2 AT All shelves have 14 bays for 3.5" low-profile FC or SATA disk drives |
| Storage Expansion Shelf to Controller Interface |
Fibre Channel-Arbitrated Loop (FC-AL) |
Storage Expansion Shelf Configurations
|
New System Configurations FC: DS14mk4 FC with ESH4 (Embedded Switched Hub 4) Electronics SATA: DS14mk2 AT with AT-FCX Electronics
Supported via Upgrade Migrations from Installed Systems FC: DS14mk4 FC with ESH4 Electronics DS14mk2 FC with ESH4 or ESH2 Electronics SATA: DS14mk2 AT with AT-FCX Electronics |
Power Supply/Cooling Fans
|
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies8
|
AC Power/Max. Current9
|
SATA: 7200 RPM drives: 3.01/1.51/7.4A @ 100VAC/200VAC/-40VDC FC: 10,000 RPM drives: 3.09/1.56/7.61A @ 100VAC/200VAC/-40VDC FC: 15,000 RPM drives: 3.96/1.94/10.22ª @ 100VAC/200VAC/-40VDC |
Thermal Rating10
|
SATA 7200 RPM drives: 1017 BTU/hr FC: 10,000 RPM drives: 1043 BTU//hr FC: 15,000 RPM drives: 1394 BTU/hr |
Operating Acoustic Noise
|
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
|
Dimensions (height/width/depth)
|
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
|
Weight
|
77 lb (35 kg) fully loaded
|
8 For detailed disk shelf specifications, refer to http://now.netapp.com/NOW/knowledge/docs/hardware/NetApp/site/guide11.htm#1792411 9 These numbers represent a single supply on, with fans on high setting at 100V, 200V, -40V DC. 10 Thermal rating, like current, is based on drive type/speed. This value is relatively constant regardless of input voltage, so only one value is required for each.
|
| |
| Disk Drive Types and Capacities Supported |
SAS 15,000 RPM: 300GB, 450GB, 600GB
SATA 7,200 RPM: 500GB, 1TB, 2TB
All shelves have 24 bays for 3.5” low-profile SAS or SATA disk drives
|
| Disk Enclosure to Controller Interface |
Serial Attached SCSI (SAS) operating at 3Gb, requires PCIe SAS Host Bus Adapter card or available embedded SAS port |
| Disk Enclosure Configurations |
Dual IOM3 (Input/Output Module) Controller modules |
| Power Supply/Cooling Fans |
Dual (SATA) or quadruple (SAS), redundant, hot-pluggable, integrated power supply/fan assemblies |
| Operating Temperature Range |
41°F to 104°F - (5°C to 40°C) |
| Nonoperating Temperature Range |
34°F to 122°F - (1°C to 50°C) |
| Relative Humidity |
20 to 80% noncondensing |
| Operating Acoustic Noise |
6.6B LwA @ 20°C |
| Input power frequency, Hz (AC) |
50 to 60 |
| Dimensions (height/width/depth) |
4 EIA U (7”, 17.8 cm)/19” IEC rack-compliant (19", 48.3 cm)/24" (61 cm) |
| Clearance Dimensions (front-cooling/rear-cooling and maintenance/front-maintenance) |
6” (15.3cm)/12” (30.5cm)/25” (55.9cm) |
| Weight |
110 lb (49.9 kg) fully loaded, 53.7 lbs (24.4 kb) without disk drives |
|
| |
|
|
| |
20A and 30A single-phase cabinets
20A Cabinet: Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors
30A Cabinet: Includes 4 power cords with NEMA L6-30P or IEC 309
|
20A Cabinet: 1 FAS3100 chassis & 12 DS14-type shelves
30A Cabinet: 1 FAS3100 chassis & 12 DS-14 type shelves |
| AC Power |
200 to 240VAC |
| Current |
20A Cabinet - Maximum 32A total 30A Cabinet - Maximum 24A total |
Dimensions (height/width/depth)
|
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
Min. Clearances
|
48" (122 cm) front and rear |
Shipping Height
|
90.6" (230 cm) |
Weight (empty)
|
275 lb (125 kg) |
|
| |
| FAS Controller and System Specifications |
Active/Active Configuration |
Single Controller Configuration |
Controller Weight
|
122 lb (55.3 kg) |
95 lb (43.1 kg) |
Controller Height
|
10.2" (26 cm), fits into 6U space |
10.24" (26 cm), fits into 6U space |
Controller Width
|
19" IEC rack-compliant (17.6", 44.7 cm) |
Controller Depth
|
24.3" (61.7 cm), 28" (71.1 cm) with cable management bracket |
Operating Temperature, Altitude, and Relative Humidity
|
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000' feet) elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature) |
Non-operating Temperature and Relative Humidity
|
-40° C to 70° C (-40° F to 158° F); 5% to 95% relative humidity, non-condensing, in original container |
Operating Acoustic Noise
|
≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
Min. Cabinet Clearances for Airflow
|
10" (25.4 cm) in front, 12" (30.5 cm) in rear |
Min. Cabinet Clearances for Service
|
30" (76.2 cm ) in front, 30" (76.2 cm) in rear |
Compliance
|
RoHS-compliant |
Safety/Emissions/Immunity
|
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, BCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3 |
|
| |
| Model |
Input Voltage |
|
Active/Active
|
Single Controller
|
|
Typical
|
Maximum |
Typical
|
Maximum |
|
One Side
|
Both Sides
|
One Side
|
Both Sides
|
| FAS3140 |
100-120VAC |
Current, A |
2.99 |
5.97 |
7.38 |
1.89 |
3.77 |
3.98 |
| Power, W |
297 |
594 |
736 |
187 |
373 |
396 |
| Thermal, BTU/hr |
1013 |
2026 |
2509 |
636 |
1272 |
1350 |
| 200-240VAC |
Current, A |
1.49 |
2.98 |
3.6 |
0.97 |
1.93 |
1.97 |
| Power, W |
291 |
581 |
712 |
183 |
366 |
385 |
| Thermal, BTU/hr |
991 |
1981 |
2427 |
625 |
1249 |
1313 |
| FAS3160 |
100-120VAC |
Current, A |
4.07 |
8.14 |
9.74 |
2.37 |
4.74 |
5.07 |
| Power, W |
405 |
810 |
969 |
235 |
470 |
505 |
| Thermal, BTU/hr |
1381 |
2761 |
3305 |
801 |
1602 |
1722 |
| 200-240VAC |
Current, A |
2.02 |
4.03 |
4.69 |
1.19 |
2.38 |
2.52 |
| Power, W |
394 |
778 |
930 |
230 |
459 |
493 |
| Thermal, BTU/hr |
1343 |
2686 |
3170 |
782 |
1564 |
1680 |
| FAS3170 |
100-120VAC |
Current, A |
4.07 |
8.14 |
9.74 |
2.37 |
4.74 |
5.07 |
| Power, W |
405 |
810 |
969 |
235 |
470 |
505 |
| Thermal, BTU/hr |
1381 |
2761 |
3305 |
801 |
1602 |
1722 |
| 200-240VAC |
Current, A |
2.02 |
4.03 |
4.69 |
1.19 |
2.38 |
2.52 |
| Power, W |
394 |
778 |
930 |
230 |
459 |
493 |
| Thermal, BTU/hr |
1343 |
2686 |
3170 |
782 |
1564 |
1680 |
|
| |