| SAN Protocol Support |
Fibre Channel Protocol (FCP) for SCSI (4/2/1Gb); fabric-attached and direct-attached; IP SAN (iSCSI); Fibre channel over Ethernet (FCoE) |
| Network Protocol Support |
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts |
| LUNs |
Up to 1,024 |
| FlexVol® Volumes |
Up to 200 per controller on FAS2020 and FAS2040. Up to 500 per controller on FAS2050. |
| Snapshot™ Copies |
Up to 51,000 per controller on FAS2020 and FAS2040. Up to 127,000 per controller on FAS2050. |
| Number of Supported Hosts |
Up to 2 ports per controller configured as front-end (host) connectivity ports
Up to 4 directly connected servers per active/active configuration
Up to 24 SAN host connected servers on FAS2020. Up to 32 SAN host connected servers on FAS2040 and FAS2050. |
| Supported Configurations |
Controller Configurations
Single controller, active/active controller with clustered failover (CFO)1
Back-End (Disk) Configurations
Dual-path, multipath HA storage (PDF) |
| Reliability |
Redundant hot-swappable controllers, cooling fans and power supplies |
| Management |
Full-duplex 10/100 Base-T Ethernet onboard console, diagnostic LED, Maintenance Center, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts |
| Security |
Virus protection, SecureAdmin, IPSec, CHAP authentication, role-based access control (RBAC) |
|
| |
| |
FC or SAS |
SATA |
FC or SAS |
SATA |
FC or SAS5 |
SATA |
| RAID 6 (RAID-DP™) |
28 (26 data disks plus 2 parity disks) |
16 (14 data disks plus 2 parity disks) |
28 (26 data disks plus 2 parity disks) |
16 (14 data disks plus 2 parity disks) |
28 (26 data disks plus 2 parity disks) |
16 (14 data disks plus 2 parity disks) |
| RAID 43 |
14 (13 data disks plus 1 parity disk) |
SATA: 7 (6 data disks plus 1 parity disk) |
14 (13 data disks plus 1 parity disk) |
SATA: 7 (6 data disks plus 1 parity disk) |
8 (7 data disks plus 1 parity disk) |
SATA: 14 (13 data disks plus 1 parity disk) |
SyncMirror® (High Resiliency RAID 1) Options:
(1) RAID-DP + RAID 1
(2) RAID 4 + RAID 1 |
FC Expansion |
Yes |
FC Expansion |
Yes |
FC Expansion |
Yes |
| Volume/Aggregate |
16TB |
16TB |
16TB |
16TB |
8TB |
8TB |
|
| |
| |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
| Max. Raw Capacity4 |
104TB |
104TB |
136TB |
136TB |
68TB |
68TB |
| Max. Number of Internal Disk Drives |
20 |
20 |
12 |
12 |
12 |
12 |
| Max. Number of Expansion Disk Drives |
84 |
84 |
124 |
124 |
56 |
56 |
| Max. Number of Total Disk Drives (Internal + External) |
104 |
104 |
136 |
136 |
68 |
68 |
| Max. Drives per Back-End (Disk) FC Loop |
84 |
84 |
84 |
84 |
56 |
56 |
| ECC Memory |
4GB |
2GB |
8GB |
4GB |
2GB |
1GB |
1 For more information about cluster configurations, refer to http://now.netapp.com/NOW/knowledge/docs/hardware/NetApp/syscfg/.
2 1) Max. capacity is derived based on the type, size, and number of the drives.
2) Max. capacity is calculated using Base10 arithmetic (1TB = 1012 bytes).
3 RAID 6 is the recommended configuration for drives greater than 144GB.
4 Maximum capacity is calculated using Base10 arithmetic (1TB = 1012 bytes).
5 Minimum software requirement of Data ONTAP 7.3.1.1 for FAS2020 |
|
| |
| Onboard I/O |
| |
Active/Active
Configuration |
Single
Controller |
Active/Active
Configuration |
Single
Controller |
Active/Active
Configuration |
Single
Controller |
| Onboard Fibre Channel Ports (target or initiator) |
4 ports of 1, 2,
or 4Gb
(auto sensing) |
2 ports of 1, 2,
or 4Gb
(auto sensing) |
4 ports of 1, 2,
or 4Gb
(auto sensing) |
2 ports of 1, 2,
or 4Gb
(auto sensing) |
4 ports of 1, 2, or 4Gb
(auto sensing) |
2 ports of 1, 2, or 4Gb
(auto sensing) |
| Onboard GbE Ports |
4 |
2 |
8 |
4 |
4 |
2 |
| Modular I/O Slots |
2 |
1 |
- |
- |
- |
- |
| Onboard SAS Ports |
- |
- |
2 |
1 |
- |
- |
|
| |
| I/O Card Support |
| |
Active/Active
Configuration |
Single
Controller |
Active/Active
Configuration |
Single
Controller |
Active/Active
Configuration |
Single
Controller |
| Dual port 4Gb FC Disk Adapter (max.) |
2 |
1 |
- |
- |
- |
- |
| Dual port 4Gb FC Tape Adapter (max.) |
2 |
1 |
- |
- |
- |
- |
| Dual port FCoE Target Adapter (max.) |
2 |
1 |
- |
- |
- |
- |
| Dual port GbE (copper or fiber) (max.) |
2 |
1 |
- |
- |
- |
- |
| Quad port 4Gb FC Disk/Tape Adapter (max.) |
2 |
1 |
- |
- |
- |
- |
| 2-port Ultra320 SCSI Tape Adapter (max) |
2 |
1 |
- |
- |
- |
- |
| 2-port 1Gb iSCSI (copper or fiber) Adapter (max) |
2 |
1 |
- |
- |
- |
- |
| Dual port 8Gb FC Disk Adapter (max.) |
2 |
1 |
- |
- |
- |
- |
|
| |
| Software |
| Operating System |
NetApp Data ONTAP® |
| Operating Systems Supported |
Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware ESX |
| Software Features |
Standard
Snapshot
FlexVol®
Thin Provisioning
RAID-DP
FlexShare®
Deduplication
Operations Manager
NearStore®
SyncMirror®
System Manager
FilerView®
FC protocol
iSCSI protocol
CIFS (included in select FAS2020 preconfigured systems)
NFS (included in select FAS2020 preconfigured FAS2020)
HTTP protocol
DNS
NDMP
NIS
FlexCache®
Maintenance Center
|
Foundation Pack
SnapRestore®
SnapVault® Primary
Provisioning Manager
Protection Pack
SnapMirror®
SnapVault Secondary
Protection Manager
Application Pack
SnapManager® (for Microsoft® Exchange, Microsoft SharePoint® Server, Microsoft SQL Server®, Oracle®, SAP®, Virtual Infrastructure)
SnapDrive® (for Windows®, UNIX®)
Single Mailbox Recovery
NetApp DSM
Server Pack
SnapManager for Virtual Infrastructure
SnapDrive (for Windows®, UNIX®)
NetApp DSM
Advanced Pack
FlexClone®
MultiStore®
SnapLock® Compliance
SnapLock Enterprise |
|
| |
| Storage Specifications |
| Disk Shelves Supported (Fibre Channel, SATA, SAS) |
DS14mk4 FC, DS14mk2 FC, DS14mk2AT
Each w/14 low-profile slots for FC and SATA disk drives
DS4243
With 24 slots for SAS or SATA disk drives |
| Disk Drive Support |
Disks Supported on New Configurations
SAS: 300GB disks, 450GB
FC: 300GB disks, 450 GB disks
Internal SATA: 500GB, 1TB disks
External SATA: 500GB, 1TB disks
Disks Supported for Legacy (Controller Upgrade) Configurations
FC: 36GB, 72GB, 144GB, 300GB, 450GB disks
SATA: 250GB, 320GB, 500GB disks, 1TB disks |
| Disk Shelf Support |
Shelves Supported on New Configurations
Embedded Switched Hub4 (ESH4)
AT-FCX
Shelves Supported for Legacy (Controller Upgrade) Configurations
Embedded Switched Hub2 (ESH2)
AT-FCX |
| Internal Disk Drive Storage Interface |
Serial Attached SCSI (SAS) |
| Disk Drive Storage Shelf Interface |
Fibre Channel-Arbitrated Loop (FC-AL) |
| Power Supply/Cooling Fans |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V) |
| AC Power/Max. Current |
100 to 120VAC/3.95A; 200 to 240VAC/1.9A |
| Thermal Rating |
1,167 Btu/hr (fully loaded shelf) |
| Operating Acoustic Noise |
58 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
| Dimensions (height/width/depth) |
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
| Weight |
77 lb (35 kg) fully loaded |
|
| |
| Vendor |
Model |
| Brocade |
Silkworm 2400/2800 (TapeSAN only) |
| Brocade |
Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E |
| McData |
ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700 |
| Cisco |
MDS 9120/9140/9216/9506/9509/9513 |
|
| |
20A and 30A single phase cabinets.
20A cabinet: Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors
30A cabinet: Includes 2 power cords with NEMA L6-30 or IEC 309 connectors |
20A cabinet: controller and up to 6 DS-14 shelves
30A cabinet: controller and up to 6 DS-14 shelves |
| AC Power |
200 to 240VAC |
| Current |
Redundant power
20A cabinet: maximum 32A total
30A cabinet: maximum 24A total |
| Dimensions (height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
| Min. Clearances |
48" (122 cm) front and rear |
| Shipping Height |
90.6" (230 cm) |
| Weight (empty) |
275 lb (125 kg) |
|
| |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240VAC only) |
88 to 264VAC, 11 to 6A, 50/60Hz |
88 to 264VAC, 9 to 4.5A, 50/60Hz |
88 to 264VAC, 9 to 4.5A, 50/60Hz |
| Weight (fully loaded) |
110 lb (50 kg) |
66 lbs (29.9kg) |
66 lbs (29.9kg) |
| Height |
6.9" (17.5 cm), fits into 4U space |
3.45" (8.76 cm), fits into 2U space |
3.45" (8.76 cm), fits into 2U space |
| Width |
19" IEC rack-compliant (17.6", 44.9 cm) |
| Depth |
24" (61 cm) |
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, non condensing (28° C wet bulb temperature) |
| Non operating Temperature and Relative Humidity |
-40° C to 70° C (-40° F to 158° F); 8% to 80% relative humidity, non condensing, in original container |
| Operating Acoustic Noise |
≤ 60 dBA sound pressure (LpA) @ normal operating conditions (at 23°C and at sea level) |
| Min. Cabinet Clearances for Airflow |
25.4 cm (10 in) in front, 30.5 cm (12 in) in rear |
| Min. Cabinet Clearances for Service |
76.2 cm (30 in) in front, 76.2 cm (30 in) in rear |
| Compliance |
RoHS-compliant (PDF) |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R, BSMI CNS14336, CCC GB 4943-2001, SABS, S Resolution 92-98
Emissions/Immunity: FCC Part 15 Class A, ICES-003, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, IEC61000-3-2, IEC61000-3-3, CoC (South Africa), BSMI, KN22
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, KN24, CISPR 24 |
|
| |
| Model |
Input Voltage |
|
Active/Active |
Single Controller |
| Typical |
Maximum |
Typical |
Maximum |
| One Side |
Both Sides |
One Side |
Both Sides |
FAS2020
no drives |
100-120VAC |
Current, A |
1.12 |
2.23 |
2.34 |
0.8 |
1.6 |
1.67 |
| Power, W |
108 |
215 |
229 |
77 |
153 |
165 |
| Thermal, BTU/hr |
366 |
731 |
780 |
261 |
521 |
563 |
| 200-240VAC |
Current, A |
0.6 |
1.18 |
1.2 |
0.45 |
0.89 |
0.9 |
| Power, W |
104 |
208 |
221 |
75 |
149 |
160 |
| Thermal, BTU/hr |
355 |
709 |
754 |
253 |
506 |
544 |
FAS2020
12x144GB SAS drives |
100-120VAC |
Current, A |
2.05 |
4.09 |
4.69 |
1.7 |
3.39 |
3.83 |
| Power, W |
200 |
400 |
464 |
165 |
330 |
377 |
| Thermal, BTU/hr |
683 |
1365 |
1583 |
563 |
1125 |
1287 |
| 200-240VAC |
Current, A |
1.11 |
2.22 |
2.34 |
0.94 |
1.87 |
1.94 |
| Power, W |
210 |
419 |
452 |
174 |
348 |
371 |
| Thermal, BTU/hr |
715 |
1429 |
1542 |
593 |
1185 |
1264 |
FAS2020
12x300GB SAS drives |
100-120VAC |
Current, A |
2.38 |
4.75 |
4.94 |
1.95 |
3.89 |
4.44 |
| Power, W |
233 |
465 |
488 |
191 |
381 |
439 |
| Thermal, BTU/hr |
794 |
1587 |
1665 |
649 |
1298 |
1497 |
| 200-240VAC |
Current, A |
1.19 |
2.37 |
2.45 |
1.08 |
2.16 |
2.23 |
| Power, W |
224 |
448 |
476 |
204 |
407 |
431 |
| Thermal, BTU/hr |
764 |
1527 |
1624 |
694 |
1388 |
1470 |
| FAS2040 no drives |
100-120VAC |
Current, A |
.98 |
1.95 |
1.96 |
.7 |
1.4 |
1.4 |
| Power, W |
94 |
187 |
192 |
67 |
133 |
137 |
| Thermal, BTU/hr |
319 |
638 |
655 |
227 |
454 |
467 |
| 200-240VAC |
Current, A |
.52 |
1.04 |
1.02 |
.391 |
.78 |
.77 |
| Power, W |
91 |
182 |
188 |
651 |
130 |
134 |
| Thermal, BTU/hr |
311 |
621 |
641 |
222 |
443 |
457 |
| FAS2040 12x300GB SAS drives |
100-120VAC |
Current, A |
2.33 |
4.66 |
4.85 |
1.98 |
3.96 |
4.08 |
| Power, W |
229 |
457 |
480 |
194 |
387 |
404 |
| Thermal, BTU/hr |
779 |
1558 |
1637 |
660 |
1320 |
1378 |
| 200-240VAC |
Current, A |
1.18 |
2.35 |
2.39 |
1 |
2 |
2.03 |
| Power, W |
224 |
447 |
464 |
189 |
378 |
392 |
| Thermal, BTU/hr |
762 |
1524 |
1582 |
645 |
1289 |
1337 |
FAS2050
no drives |
100-120VAC |
Current, A |
1.19 |
2.37 |
2.62 |
0.9 |
1.8 |
2.33 |
| Power, W |
114 |
227 |
256 |
87 |
173 |
222 |
| Thermal, BTU/hr |
387 |
773 |
874 |
295 |
589 |
758 |
| 200-240VAC |
Current, A |
0.62 |
1.24 |
1.35 |
0.5 |
0.99 |
1.23 |
| Power, W |
111 |
222 |
250 |
108 |
168 |
217 |
| Thermal, BTU/hr |
379 |
758 |
851 |
287 |
574 |
739 |
FAS2050
20x144GB SAS drives |
100-120VAC |
Current, A |
2.84 |
5.68 |
6.31 |
2.38 |
4.76 |
5.64 |
| Power, W |
279 |
558 |
628 |
233 |
465 |
560 |
| Thermal, BTU/hr |
951 |
1902 |
2142 |
794 |
1587 |
1909 |
| 200-240VAC |
Current, A |
1.45 |
2.89 |
3.09 |
1.33 |
2.65 |
2.82 |
| Power, W |
225 |
550 |
600 |
251 |
502 |
547 |
| Thermal, BTU/hr |
938 |
1876 |
2044 |
855 |
1710 |
1864 |
FAS2050
20x300GB SAS drives |
100-120VAC |
Current, A |
3.34 |
6.68 |
7.51 |
2.96 |
5.92 |
6.62 |
| Power, W |
330 |
659 |
747 |
292 |
583 |
658 |
| Thermal, BTU/hr |
1124 |
2247 |
2547 |
994 |
1988 |
2243 |
| 200-240VAC |
Current, A |
1.71 |
3.41 |
3.73 |
1.38 |
2.76 |
3.27 |
| Power, W |
328 |
655 |
728 |
262 |
523 |
636 |
| Thermal, BTU/hr |
1116 |
2232 |
2483 |
891 |
1782 |
2168 |
|
| |