NetApp FAS8000 Technical Specifications

Technical specifications for the NetApp FAS8000 Series unified scale-out storage

See technical specifications that include the NetApp FAS6290, FAS6250 and FAS6220

See technical specifications that include the NetApp® FAS3250 and FAS3220.

View specifications for:

All data in this table applies to dual controller hybrid and disk-only configurations. See the All-Flash FAS datasheet PDF for information about all-flash configurations.


FAS8080 EXFAS8060FAS8040FAS8020
NAS scale-out1-24 nodes (12 HA Pairs)
Maximum Drives17,28014,4008,6405,760
Maximum Capacity103PB86PB51PB34PB
Maximum Flash Pool Capacity1728TB864TB576TB288TB
Maximum All-flash FAS Capacity4.6PB4.6PB4.6PB4.6PB
Maximum memory3,072GB1,536GB768GB576GB
SAN scale-out1-8 nodes (4 HA Pairs)
Maximum Drives5,7604,8002,8801,920
Maximum Capacity34PB28PB17PB11.5PB
Maximum Flash Pool Capacity576TB288TB192TB96TB
Maximum raw capacity: All-flash1.5PB1.5PB1.5PB1.5PB
Maximum memory1,024GB512GB256GB192GB
Cluster Interconnect2, 4 or 6 x 10GbE2 or 4 x 10GbE2 or 4 x 10GbE2 x 10GbE
Per HA Pair Specifications (active-active dual controller)

FAS8080 EXFAS8060FAS8040FAS8020
Maximum Capacity8640TB7200TB4320TB2880TB
Maximum Flash Pool Capacity144TB72TB48TB24TB
Maximum All-Flash FAS Capacity384TB384TB384TB384TB
Maximum Drives1,4401,200720480
Controller Form FactorDual enclosure HA;
2 controllers in two 6U chassis; total of 12U
Single enclosure HA;
2 controllers in single 6U chassis
Single enclosure HA;
2 controllers in single 6U chassis
Single enclosure HA;
2 controllers in single 3U chassis
Memory256GB128GB64GB48GB
Maximum Flash Cache24TB8TB4TB3TB
Maximum Flash Pool144TB72TB48TB24TB
Combined Flash Total144TB72TB48TB24TB
NVRAM32GB16GB16GB8GB
PCIe Expansion Slots24884
Onboard I/O: UTA2
(10GbE/FCoE, 16Gb FC)
8884
Onboard I/O: 10GbE8884
Onboard I/O: GbE8884
Onboard I/O, 6Gb SAS8884
Storage Networking SupportedFC; FCoE; iSCSI; NFS; pNFS; CIFS/SMB; HTTP; FTP
OS VersionData ONTAP 8.2.2 RC1 or higherData ONTAP 8.2.1 RC2 or higher
High-Availability FeaturesAlternate Control Path (ACP); Ethernet-based service processor and Data ONTAP® management interface; redundant hot-swappable controllers, cooling fans, power supplies and optics
Supported Configurations




Data ONTAP 8.2.x
cDOT Configurations
  • Single node cluster
  • Two-node switchless or switched cluster
  • Clusters of HA pairs
7-Mode Configurations
  • Single Controller:
  • Active-active controller with controller failover and multipath HA storage

7-Mode MetroCluster Configurations

  • Active-active controller with stretch (non-switched storage) MetroCluster
  • Active-active controller with fabric-attached (switched storage) MetroCluster

Supported Configurations




Data ONTAP 8.3


cDOT Configurations

  • Single-node cluster
  • Two-node switchless or switched cluster
  • Clusters of HA pairs

MetroCluster cDOT Configurations

2 x two-node switched or switchless clusters with fabric-attached (switched) storage. 4 nodes total – a 2-node active/active cluster at each site.

Disk Shelves SupportedDS2246 (2U; 24 drives, 2.5” SFF)
DS4246 (4U; 24 drives, 3.5” LFF)
DS4486 (4U; 48 drives, 3.5” LFF)
DS4243 (4U; 24 drives, 3.5" LFF) supported for upgrades only
DS14 disk shelves (mk2-AT, mk4) are supported for upgrades only
See NetApp Disk Shelves and Storage Media for more details on each disk shelf and supported drive types.
Maximum RAID Group Sizes

RAID 6 (RAID-DP)

Performance Disk: 28 (26 data disks plus 2 parity disks)

Capacity Disk: 20 (18 data disks plus 2 parity disks)

 

RAID 4

Performance Disk: 14 (13 data disks plus 1 parity disk)

Capacity Disk: 7 (5 data disks plus q parity disk)

RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
Operating Systems SupportedWindows 2000, Windows Server 2003, Windows Server 2008, Windows Server 2012, Windows XP, Linux®, Oracle Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX
Max. Number of LUNs8,192
Number of Supported SAN HostsUp to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol VolumesUp to 1,000 per controller (clustered Data ONTAP) up to 500 per controller (7-Mode)
Snapshot CopiesUp to 255,000 per controller
Maximum Volume Size100TB100TB100TB70TB
Maximum Aggregate Size400TB400TB324TB324TB
Maximum port count includes integrated ports and PCIe expansion slots
FC Target Ports (16Gb autoranging)64242412
FC Target Ports (4Gb or 8Gb)64404020
FCoE Target Ports, UTA (max.)32242412
10GbE Ports (max.)64323216
GbE Ports (max.)72404020
6Gb SAS Ports (max.)56404020
FC Initiator Ports (max.)72404020
Maximum Adapters
Dual 10GbE (optical or copper)16884
Dual 10Gbase-T (RJ-45, CAT 6A-E)16884
Quad GbE (copper)16884
Dual 10GbE/FCoE 16Gb FC Unified Target Adapter 2 (UTA2, optical or copper for 10GbE/FCoE deployments, optical for 16Gb FC)24884
8Gb FC Target16884
Flash Cache Performance Acceleration Module (2TB)12420
Flash Cache Performance Acceleration Module (1TB)24842
Flash Cache Performance Acceleration Module (512GB)24884
Quad 6Gb SAS Storage HBA12884
Quad 4Gb FC Storage/Tape HBA (fibre)16884
System Environmental Specifications

FAS8080 EXFAS8060FAS8040FAS8020
Thermal Rating (at 200V)2,880 BTU (typical, per enclosure)

3,252 BTU (worst case, per enclosure)
2,031 BTU (typical)

2,362 BTU (worst case)
1,495 BTU (typical)

1,843 BTU (worst case)
1,205 BTU (typical)

1,450 BTU (worst case)
Weight119.8 lb121 lb121 lb78 lb
Height12U (6U per enclosure)6U6U3U
Width19" IEC rack-compliant (17.6”, 44.7 cm)
Depth24.3” (28.9” w/cable management)
Operating Temperature, Altitude and Relative Humidity10°C to 40°C (50°F to 104°F); at <= 3,000 m (at <= 10,000 feet) elevation; 20% to 80% relative humidity, non-condensing (28°C wet bulb temperature)
Non-operating Temperature and Relative Humidity-40°C to 65°C (-40°F to 149°F); 5% to 95% relative humidity, non-condensing, in original container
Operating Acoustic Noise
FAS8020:
  • Declared sound power (LwAd) per ISO 9296: 7.8 Bel
  • Sound pressure (LpAm) (bystander positions): 62.6 dB

FAS8040/FAS8060:
  • Declared sound power (LwAd) per ISO 9296: 7.6 Bel
  • Sound pressure (LpAm) (bystander positions): 62.9 dB

FAS8080 EX:
  • Declared sound power (LwAd) per ISO 9296: 7.5 Bel @ normal operating conditions (at 23°C and at sea level)
ComplianceRoHS-compliant PDF
Safety/Emissions/ImmunitySafety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, CU, BIS, BSMI, SONCAP, NRCS LOA (South Africa)

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI
NetApp Systems Cabinet

FAS8080 EXFAS8060FAS8040FAS8020
Rack Space42U
Dimensions (height/width/depth)78.75" (200 cm)/23.6" (60 cm)/44.3" (112.5 cm)
Minimum Cabinet Clearances for Airflow10" (25.4 cm) front and 12” (30.5 cm) rear
Minimum Cabinet Clearances for Service30” (76.3 cm) front and rear, 12” top
AC Power200 to 240VAC
Current30A Single Phase or 3-Phase
Weight (empty)307 lbs (138 kg)
FeaturesSplit rear door with cable egress opening, reversible front door (left or right handed)
FC and FCoE Switch Support

NetApp offers broad support for FC and FCoE switches. A list of switches available through NetApp can be foundhere. For the complete list of supported switches, please consult the interoperability matrix found on the NetApp support site. Login access is required.