Operating System
|
NetApp Data ONTAP® 7.2.4 or later software
|
|
Operating Systems Supported
|
Windows® 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware, ESX
|
|
Standard Software Features
|
Integrated automatic RAID manager, including RAID-DP™, Snapshot™, Fast Boot, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, FlexVol®, FlexShare™, SSH, Maintenance Center, Network Data Management Protocol (NDMP)
|
|
File Service and Other Protocol Support
|
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts
|
|
SAN Protocol Support
|
Fibre Channel Protocol (FCP) (8/4/2/1Gb); fabric-attached and direct-attached; IP SAN (iSCSI), Fibre Channel over Ethernet (FCoE)
|
|
Licensed Software Products
|
FlexClone
™,
FlexCache
,
MultiStore
®,
SnapMirror
®,
SnapRestore
®, SnapDrive®,
SnapManager
® for Microsoft Exchange,
SnapManager
for Microsoft SQL Server,
SnapManager
for Oracle®,
Single Mailbox Recovery
,
SnapVault
®, SnapMover®,
SnapLock
® Compliance, SnapLock Enterprise,
SyncMirror
®,
MetroCluster
,
CommandCentral™ Storage
,
Protection Manager
2
,
File Storage Resource Manager
, SAN Manager,
Operations Manager
3
, ApplianceWatch™ for HP Openview, ApplianceWatch for Tivoli®
|
|
Standard Hardware Features
|
ROHS-compliant, full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220 V 42U 19" system cabinet
|
|
Maximum RAID Group Sizes
|
RAID 6 (RAID-DP) FC – 28 (26 data disks plus 2 parity disks), SATA – 16 (14 data disks plus 2 parity disks)
RAID 44 FC – 14 (13 data disks plus 1 parity disk), SATA – 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
|
|
Supported Configurations
|
Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA600
|
|
Disk Shelves Supported (Fibre Channel, SATA) and Configurations
|
DS14, DS14mk2 FC, DS14mk4 FC, DS14mk2AT
Dual-path
DS4243, MPHA (MultiPath High Availability)
|
|
Disk Drive Capacities Supported
|
FC-91/181/361/721/300GB, 450GB, 600GB
SATA-500GB, 1TB, 2TB
SAS: 300GB, 450GB, 600GB
|
1
9/18/36/72GB drives are supported but not currently shipping.
2
Protection Manager was previously known as Business Continuance Option.
3
Operations Manager was previously known as DataFabric® Manager (DFM).
4
RAID 6 is the recommended configuration for drives greater than 144GB.
|
|
| |
| |
Active/Active Configuration
|
Single Controller
|
Active/Active Configuration
|
Single Controller
|
|
Max. Raw Capacity
(5), (6)
|
2,352TB
|
2,352TB
|
1680TB
|
1680TB
|
|
Max. Number of Disk Drives
|
1,176
|
1,176
|
840
|
840
|
|
Max. Number of FC Loops (dual attach)
|
14
|
14
|
10
|
10
|
|
Max. Drives per FC Loop
|
84 |
|
Max. Volume/Aggregate Size
|
16TB |
|
Max. Number of LUNs per Controller
|
2048 |
|
ECC Memory
|
64GB
|
32GB
|
32GB
|
16GB
|
|
Nonvolatile Memory
|
4GB
|
2GB
|
1GB
|
512MB
|
|
Onboard GbE Ports
|
12
|
6
|
12
|
6
|
|
Onboard 4Gb FC Ports (target or initiator)7
|
16
|
8
|
16
|
8
|
5
Max. capacity is derived based on the type, size, and number of the drives.
6
Max. capacity is calculated using Base10 arithmetic (i.e., 1TB = 1,000,000,000,000 bytes).
7
Autosensing ports: 1, 2, 4Gb.
|
|
| |
| |
Active/Active
Configuration
|
Single
Controller
|
Active/Active
Configuration
|
Single
Controller
|
|
PCI Express Expansion Slots
|
10 |
5 |
10 |
5 |
|
PCI-X Expansion Slots
|
6 |
3 |
6 |
3 |
Optional Network Connectivity (max.)
Quad GbE TOE (copper) Cards
Quad GbE (copper) Cards
Single 10GbE TOE (fiber) 10GBASE-SR Cards
Dual 10GbE TOE (fiber) 10GBASE-SR Cards
Dual GbE (copper or fiber) Cards
Dual iSCSI (copper or fiber) Adapters
|
10
10
4
10
10
6
|
5
5
2
5
5
3
|
10
10
4
10
10
6
|
5
5
2
5
5
3
|
|
Dual 4Gb FC Initiator Adapters (max.)
|
10
|
5
|
10
|
5
|
|
Quad 4Gb FC Initiator Adapters (max.)
|
10
|
5
|
10
|
5
|
|
Dual 4Gb FC Target (SAN) Adapters (max.)
|
8
|
4
|
8
|
4
|
|
Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)1
|
8
|
4
|
8
|
4
|
|
Dual FC, LVD SCSI Tape Adapters (max.)
|
6
|
3
|
6
|
3
|
|
4port SAS HBA
|
|
|
|
|
|
Performance Acceleration Module (PAM)
|
10
|
5
|
8
|
4
|
|
512GB Flash Cache1
(max cards)
|
8
|
4
|
4
|
2
|
1
Requires Data ONTAP 7.3.2 or later, 8.0.1 or later
|
| |
|
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only)
|
100 to 120VAC, 11.2A (typical)
200 to 240VAC, 5.8A (typical)
19.4A (max.) @ 100VAC
9.6A (max.) @ 200VAC |
100 to 120VAC, 5.6A (typical)
200 to 240VAC, 2.9A (typical)
9.7A (max.) @ 100VAC
4.8A (max.) @ 200VAC |
|
Thermal Rating
|
3740 Btu/hr, 1096W (typical) |
1870 Btu/hr, 548W (typical) |
|
Weight
|
242 lb (109.6 kg) |
121 lb (54.8 kg) |
|
Height
|
20.8" (52.8 cm), fits into 12U space |
10.3" (26.2 cm), fits into 6U space |
|
Width
|
19" IEC rack-compliant (17.53", 44.53 cm) |
|
Depth
|
23.5" (59.7 cm), 29.05" (73.8 cm) with cable management bracket |
|
Operating Temperature, Altitude, and Relative Humidity
|
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature) |
|
Nonoperating Temperature and Relative Humidity
|
-40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, noncondensing, in original container |
|
Operating Acoustic Noise
|
56.5 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
|
Min. Cabinet Clearances
|
1.85" (4.7 cm) for bezel, 3" (7.6 cm) for cable radius |
|
Min. Service Clearances
|
25" (63.5 cm) from front of cabinet; 40" (76 cm) from rear of cabinet |
|
| |
|
Disk Drive Storage Shelf
|
DiskShelf14 family—DS14, DS14mk4 FC, and DS14mk2AT; each w/14 low-profile slots for FC and SATA disk drives |
|
Disk Drive Storage Shelf Interface
|
PCI-based Fibre Channel-Arbitrated Loop (FC-AL) |
|
DiskShelf14 Interface
|
Dual, redundant electronically switched hub (ESH4) modules or dual, redundant ATA modules |
|
Power Supply/Cooling Fans
|
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V) |
|
AC Power/Max. Current
|
100 to 120VAC/4.52A; 200 to 240VAC/2.23A |
|
Thermal Rating
|
1,538 Btu/hr (fully loaded shelf) |
|
Operating Acoustic Noise
|
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
|
Dimensions (height/width/depth)
|
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
|
Weight
|
77 lb (35 kg) fully loaded |
|
| |
|
Disk Drive Types and Capacities Supported
|
SAS 15,000 RPM: 300GB, 450GB, 600GB
SATA 7,200 RPM: 500GB, 1TB, 2 TB
All shelves have 24 bays for 3.5” low-profile SAS or SATA disk drives |
|
Disk Enclosure to Controller Interface
|
Serial Attached SCSI (SAS) operating at 3Gb, requires PCIe SAS Host Bus Adapter card or available embedded SAS port |
|
Disk Enclosure Configurations
|
Dual IOM3 (Input/Output Module) Controller modules |
|
Power Supply/Cooling Fans
|
Dual (SATA) or quadruple (SAS), redundant, hot-pluggable, integrated power supply/fan assemblies |
|
Operating Temperature Range
|
41°F to 104°F - (5°C to 40°C) |
|
Nonoperating Temperature Range
|
34°F to 122°F - (1°C to 50°C) |
|
Relative Humidity
|
20 to 80% noncondensing |
|
Operating Acoustic Noise
|
6.6B LwA @ 20°C |
|
Input power frequency, Hz (AC)
|
50 to 60 |
|
Dimensions (height/width/depth)
|
4 EIA U (7”, 17.8 cm)/19” IEC rack-compliant (19”, 48.3 cm)/24” (61 cm) |
|
Clearance Dimensions (front-cooling/rear-cooling and maintenance/front-maintenance)
|
6” (15.3cm)/12” (30.5cm)/25” (55.9cm) |
|
Weight
|
110 lb (49.9 kg) fully loaded, 53.7 lbs (24.4 kb) without disk drives |
|
| |
|
FC = Fibre Channel; LVD = Low Voltage Differential.
|
|
| |
|
Includes 2 Sets of Dual 16A, Zero U Power Distribution Units (PDUs) or
1 Set of 24A Zero U PDUs
|
Accommodates 1 controller and 12 disk shelves or 2 controllers and 10 disk shelves or 14 disk shelves
1 controller and 10 disk shelves or 2 controllers and 6-8 disk shelves or 11-14 disk shelves only |
|
AC Power
|
200 to 240VAC |
|
Current
|
32A total-2 redundant sets of dual 16A cables with NEMA L6-20 or IEC 309 connectors or Australia AS/NZ53123-20; 24A total-2 redundant cables with NEMA L6-30 or IEC 309 connectors |
|
Dimensions (height/width/depth)
|
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
|
Min. Clearances
|
48" (122 cm) front and rear |
|
Shipping Height
|
90.6" (230 cm) |
|
Weight (empty)
|
275 lb (125 kg) |
|
| |
|
Safety/Emissions/Immunity
|
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI |
|