Rack units
|
2U |
4U |
4U |
3U |
|
Drives per enclosure
|
24 |
24 |
48 |
14 |
|
Drives per rack unit
|
12 |
6 |
12 |
~4.7 |
|
Drive form factor
|
2.5” small form factor |
3.5” large form factor |
3.5” large form factor |
3.5” large form factor |
|
Drive carrier
|
Single drive |
Single drive |
Tandem (dual) drives |
Single drive |
|
High-capacity disk drives
|
N/A |
DS4243: 1TB, 2TB, and 3TB at 7.2k RPM
DS4246: 1TB and 3TB at 7.2k RPM in Flash Pool configurations only at this time[1] |
3TB at 7.2k RPM |
DS14mk2 AT: 1TB and 2TB |
Controllers supported with
high-capacity disk drives
|
N/A |
FAS2000 series, FAS2200 series, FAS/V3070, FAS/V3100 series, FAS/V3200 series, FAS/V6000 series, FAS/V6200 series |
FAS/V3240, FAS/V3270, FAS/V6000 series, FAS/V6200 series |
FAS200 series, FAS2000 series, FAS/V3000 series, FAS/V3100 series, FAS/V3200 series, FAS/V6000 series, and FAS/V6200 series |
|
NetApp® Data ONTAP® version required for high-capacity disk drives
|
N/A |
7.3.3P2 or later,
8.0P1 or later |
8.1.1 or later |
7.2.1 or later, 8.0 or later |
|
Performance disk drives
|
450GB and 600GB at 10k RPM |
DS4243: 300GB, 450GB, and 600GB at 15k RPM
DS4246: Not supported[1] |
N/A |
DS14mk4 FC: 300GB, 450GB, and 600GB at 15k RPM |
Controllers supported with
performance disk drives
|
FAS2040, FAS2050, FAS/V3070, FAS/V3100 series, FAS/V3200 series, FAS/V6000 series, and FAS/V6200 series |
FAS2000 series, FAS2200 series, FAS/V3070, FAS/V3100 series, FAS/V3200 series, FAS/V6000 series, and FAS/V6200 series |
N/A |
FAS200 series, FAS2000 series, FAS/V3000 series, FAS/V3100 series, FAS/V3200 series, FAS/V6000 series, and FAS/V6200 series |
|
Data ONTAP version required for performance disk drives
|
For FAS2040/2050:
7.3.4 or later, 8.0.1 or later
For other systems:
7.3.3P2 or later, 8.0P1 or later |
7.3.3P2 or later, 8.0P1 or later |
N/A |
7.2.1 or later, 8.0 or later |
|
Self-encrypting disk drives[2]
|
600GB at 10k RPM,
256-bit AES,
FIPS 140-2 compliant |
DS4243: 600GB at 15k RPM,
128-bit AES,
FIPS 140-2 compliant
DS4246: Not supported[1] |
N/A |
N/A |
Controllers supported with
self-encrypting disk drives
|
FAS2040, FAS2240-2, FAS/V3200 series, and FAS/V6200 series |
FAS2040, FAS2240-2, FAS/V3200 series, and FAS/V6200 series |
N/A |
N/A |
|
Data ONTAP version required for self-encrypting disk drives
|
8.1RC3 (7-Mode only) or later |
8.1RC3 (7-Mode only) or later |
N/A |
N/A |
|
Solid state drives
|
N/A |
DS4243: 100GB
DS4246: 100GB in Flash Pool configurations only at this time[1] |
N/A |
N/A |
Controllers supported with
solid state drives in data aggregates
|
N/A |
FAS2200 series, FAS/V3160, FAS/V3170, FAS/V3200 series,
FAS/V6040, FAS/V6080, and FAS/V6200 series |
N/A |
N/A |
Controllers supported in configurations using only
solid state drives
|
N/A |
FAS2200 series, FAS/V3200 series, FAS/V6210, and FAS/V6240
|
N/A |
N/A |
|
Data ONTAP version required for solid state drives
|
N/A |
8.0.1 or later for most systems;
8.1 or later is required for FAS2240-2 and FAS2240-4;
8.1.1 or later is required for Cluster-Mode, all-SSD, and Flash Pool configurations |
N/A |
N/A |
|
Mixed SSDs and HDDs in the same disk shelf
|
N/A |
DS4243 and DS4246:
100GB SSDs with 1TB HDDs;
100GB SSDs with 3TB HDDs |
N/A |
N/A |
|
Shelf architecture and I/O bandwidth
|
SAS operating at 6Gbps. Connections require PCIe SAS host bus adapter card or available embedded SAS port. |
DS4243: SAS operating at 3Gbps;
DS4246: SAS operating at 6Gbps;
Both: Connections require PCIe SAS host bus adapter card or available embedded SAS port. |
SAS operating at 6Gbps. Connections require PCIe SAS host bus adapter card or available embedded SAS port. |
DS14mk4 FC operating at 4Gbps: 144GB, 300GB, 450GB, 600GB 15k RPM drives;
DS14mk4 FC operating at 2Gbps: 72GB 10k/15k RPM, 144GB/300GB 10k RPM drives;
DS14mk2 AT operating at 1.5Gbps: 320GB SATA |
|
Shelf I/O modules
|
Dual IOM6 modules |
FAS4243: Dual IOM3 modules;
FAS4246: Dual IOM6 modules
|
Dual IOM6 modules |
DS14mk4 FC: ESH4 DS14mk2 AT: AT-FCX |
|
Interface to controller
|
6Gbps SAS |
DS4243: 3Gbps SAS
DS4246: 6Gbps SAS |
6Gbps SAS |
DS14mk4 FC: 4Gbps FC-AL
DS14mk2 AT: 2Gbps FC-AL |
|
Power supply/cooling fans
|
Dual, hot-pluggable, integrated power supply/fan assemblies |
Redundant, hot-pluggable, integrated power supply/fan assemblies;
Dual supplies required for high-capacity disk drives and SSDs;
Quadruple supplies required for performance disk drives and self-encrypting disk drives. |
Redundant, hot-pluggable, integrated power supply/fan assemblies;
Quadruple supplies required. |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies |
AC input power voltage
(autoranging, VRMS)
|
100–120V or 200–240V |
|
AC input power frequency
|
50–60 Hz |
|
DC input power
|
Not available |
|
Weight—fully loaded
|
49 lbs (22.2 kg) |
110 lbs (49.9 kg) |
150lbs (68kg) |
DS14mk2 AT: 68 lbs. (30.8 kg)
DS14mk4 FC: 77 lbs. (35 kg) |
|
Dimensions
|
Height: 3.4 in. (8.5 cm)
Width: 19 in. (48.0 cm)
Depth: 19.1 in. (48.4 cm) |
Height: 7 in. (17.8 cm)
Width: 19 in. (48.3 cm)
Depth: 24 in. (61 cm) |
Height: 7 in. (17.8 cm)
Width: 19 in. (48.3 cm)
Depth: 28 in. (71 cm) |
Height: 5.25 in. (13.3 cm)
Width: 19" in. (44.7 cm)
Depth: 20" (50.85 cm) |
|
Clearance dimensions
|
Front—cooling: 6 in. (15.3 cm)
Front—maintenance: 12 in. (30.5 cm)
Rear—cooling and maintenance: 25 in. (55.9 cm) |
Front—cooling: 6 in. 15.3 cm)
Front—maintenance: 12 in. (30.5 cm)
Rear—cooling and maintenance: 25 in. (55.9 cm) |
Front—cooling: 6 in. (15.3 cm)
Front—maintenance: 12 in. (30.5 cm)
Rear—cooling and maintenance: 36 in.(91.4cm) |
Front—cooling: 6 in. (15.3 cm)
Front—maintenance: 12 in. (30.5 cm)
Rear—cooling and maintenance: 25 in. (55.9 cm) |
|
Operating acoustic noise
|
6.2 bels LwAd (2 PCMs) |
7.0 bels LwAd (4 PCMs) |
58 dBA @ 23° C |
|
Temperature
|
Operating: 50° F to 104° F (10° C to 40° C)
Nonoperating: –40° F to 158° F (–40° C to 70° C) |
Operating: 41° F to 104° F (5° C to 40° C)
Nonoperating: –40° F to 140° F (–40° C to 60° C) |
|
Relative humidity
|
Operating: 20% to 80% noncondensing;
Nonoperating: 10 to 95% noncondensing |
20% to 80% noncondensing |
|
Altitude
|
Operating: 0 to 10,000 ft (0 to 3,045 m)
Nonoperating: –1,000 to 40,000 ft (–305 to 12,192 m) |
Specification not available |