Operating System
|
NetApp Data ONTAP® 7.2.4 or later software
|
|
Operating Systems Supported
|
Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware, ESX
|
|
Standard Software Features
|
Integrated automatic RAID manager, including RAID-DP™, Snapshot™, Fast Boot, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, FlexVol®, FlexShare™, SSH, Maintenance Center, Network Data Management Protocol (NDMP)
|
|
File Service and Other Protocol Support
|
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts
|
|
SAN Protocol Support
|
Fibre Channel Protocol (FCP) for SCSI (2Gb and 4Gb); fabric-attached and direct-attached; IP SAN (iSCSI), Fibre Channel over Ethernet (FCoE)
|
|
Licensed Software Products
|
FlexClone™, FlexCache, MultiStore®, SnapMirror®, SnapRestore®, SnapDrive®, SnapManager® for Microsoft Exchange, SnapManager for Microsoft SQL Server, SnapManager for Oracle®, Single Mailbox Recovery, SnapVault®, SnapMover®, SnapLock® Compliance, SnapLock Enterprise, SyncMirror®, MetroCluster, CommandCentral™ Storage, Protection Manager2 ,File Storage Resource Manager, SAN Manager, Operations Manager3, ApplianceWatch™ for HP Openview, ApplianceWatch for Tivoli®
|
|
Standard Hardware Features
|
ROHS-compliant, full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220 V 42U 19" system cabinet
|
|
Maximum RAID Group Sizes
|
RAID 6 (RAID-DP) FC – 28 (26 data disks plus 2 parity disks), SATA – 16 (14 data disks plus 2 parity disks)
RAID 44 FC – 14 (13 data disks plus 1 parity disk), SATA – 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
|
|
Disk Shelves Supported (Fibre Channel, SATA) and Configurations
|
DS14, DS14mk2 FC, DS14mk4 FC, DS14mk2AT
Dual-path
DS4243, MPHA (MultiPath High Availability)
|
|
Disk Drive Capacities Supported
|
FC-91/181/361/721/144/300GB
SATA-250GB, 500GB, 750GB, 1TB
SAS: 300GB, 450GB, 600GB
|
1 9/18/36/72GB and 250/320GB drives are supported but not currently shipping.
1 Protection Manager was previously known as Business Continuance Option.
2 Operations Manager was previously known as DataFabric® Manager (DFM).
3 RAID 6 is the recommended configuration for drives greater than 144GB.
4Requires ONTAP 7.3 .
5Please see V-Series hardware compatibility matrix for latest storage array and SAN switch connectivity support http://now.netapp.com/NOW/knowledge/docs/V-Series/supportmatrix/V-Series_SupportMatrix.pdf |
|
| |
| |
Active/Active Configuration |
Single Controller |
Active/Active Configuration |
Single Controller |
| Max. Raw Capacity
* |
1,176TB
|
1,176TB
|
840TB
|
840TB
|
| Max. Number of Disk Drives |
1,176
|
1,176
|
840
|
840
|
| Max. Number of FC Loops (dual attach) |
14
|
14
|
10
|
10
|
| Max. Drives per FC Loop |
84 |
| Max. Volume/Aggregate Size |
16TB |
| Max. Number of LUNs per Controller |
2048 |
| ECC Memory |
64GB
|
32GB
|
32GB
|
16GB
|
| Nonvolatile Memory |
4GB
|
2GB
|
1GB
|
512MB
|
| Onboard GbE Ports |
12
|
6
|
12
|
6
|
| Onboard 4Gb FC Ports (target or initiator)7 |
16
|
8
|
16
|
8
|
*Max. capacity is derived based on the type, size, and number of the drives.
*Max. capacity is calculated using Base10 arithmetic (i.e., 1TB = 1,000,000,000,000 bytes). |
|
| |
|
Storage Arrays
|
IBM
Enterprise Storage Server (ESS), DS4000 Storage
HDS
USP Platform, AMS, Lightning Series,Thunder Series,
SANRISE Series (Japan Only)
HP
StorageWorks XP Arrays, StorageWorks Enterprise Virtual Arrays
EMC
Symmetrix, Clariion
Fujitsu
ETERNUS Platform
3PAR
InServ Family
SUN
StorageTek |
|
|
| |
|
Vendor
|
Model
|
|
Brocade
|
Silkworm
|
|
Cisco
|
MDS
|
|
McDATA
|
Sphereon,Intrepid
|
|
| |
| |
Active/Active
Configuration |
Single
Controller |
Active/Active
Configuration |
Single
Controller |
| PCI Express Expansion Slots |
10 |
5 |
10 |
5 |
| PCI-X Expansion Slots |
6 |
3 |
6 |
3 |
Optional Network Connectivity (max.)
Quad GbE TOE (copper) Cards
Quad GbE (copper) Cards
Single 10GbE TOE (fiber) 10GBASE-SR Cards
Dual 10GbE TOE (fiber) 10GBASE-SR Cards
Dual GbE (copper or fiber) Cards
Dual iSCSI (copper or fiber) Adapters |
10
10
4
10
10
6 |
5
5
2
5
5
3 |
10
10
4
10
10
6 |
5
5
2
5
5
3 |
|
Dual 4Gb FC Initiator Adapters (max.)
|
10
|
5
|
10
|
5
|
|
Quad 4Gb FC Initiator Adapters (max.)
|
10
|
5
|
10
|
5
|
|
Dual 4Gb FC Target (SAN) Adapters (max.)
|
8
|
4
|
8
|
4
|
|
Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)1
|
8
|
4
|
8
|
4
|
|
Dual FC, LVD SCSI Tape Adapters (max.)
|
6
|
3
|
6
|
3
|
|
4port SAS HBA
|
|
|
|
|
|
Performance Acceleration Module (PAM)
|
10
|
5
|
8
|
4
|
|
512GB Flash Cache7
(max cards)
|
8
|
4
|
4
|
2
|
6Requires Data ONTAP 7.3
7Requires Data ONTAP 7.3.2 or later, 8.0.1 or later |
| |
| AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) |
100 to 120VAC, 11.2A (typical)
200 to 240VAC, 5.8A (typical)
19.4A (max.) @ 100VAC
9.6A (max.) @ 200VAC |
100 to 120VAC, 5.6A (typical)
200 to 240VAC, 2.9A (typical)
9.7A (max.) @ 100VAC
4.8A (max.) @ 200VAC |
| Thermal Rating |
3740 Btu/hr, 1096W (typical) |
1870 Btu/hr, 548W (typical) |
| Weight |
242 lb (109.6 kg) |
121 lb (54.8 kg) |
| Height |
20.8" (52.8 cm), fits into 12U space |
10.3" (26.2 cm), fits into 6U space |
| Width |
19" IEC rack-compliant (17.53", 44.53 cm) |
| Depth |
23.5" (59.7 cm), 29.05" (73.8 cm) with cable management bracket |
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature) |
| Nonoperating Temperature and Relative Humidity |
-40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, noncondensing, in original container |
| Operating Acoustic Noise |
56.5 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Min. Cabinet Clearances |
1.85" (4.7 cm) for bezel, 3" (7.6 cm) for cable radius |
| Min. Service Clearances |
25" (63.5 cm) from front of cabinet; 40" (76 cm) from rear of cabinet |
|
| |
| Disk Drive Storage Shelf |
DiskShelf14 family—DS14, DS14mk4 FC, and DS14mk2AT; each w/14 low-profile slots for FC and SATA disk drives |
| Disk Drive Storage Shelf Interface |
PCI-based Fibre Channel-Arbitrated Loop (FC-AL) |
| DiskShelf14 Interface |
Dual, redundant electronically switched hub (ESH4) modules or dual, redundant ATA modules |
| Power Supply/Cooling Fans |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V) |
| AC Power/Max. Current |
100 to 120VAC/4.52A; 200 to 240VAC/2.23A |
| Thermal Rating |
1,538 Btu/hr (fully loaded shelf) |
| Operating Acoustic Noise |
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Dimensions (height/width/depth) |
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
| Weight |
77 lb (35 kg) fully loaded |
|
| |
| Disk Drive Types and Capacities Supported |
SAS 15,000 RPM: 300GB, 450GB, 600GB
SATA 7,200 RPM: 500GB, 1TB, 2TB
All shelves have 24 bays for 3.5” low-profile SAS or SATA disk drives
|
| Disk Enclosure to Controller Interface |
Serial Attached SCSI (SAS) operating at 3Gb, requires PCIe SAS Host Bus Adapter card or available embedded SAS port |
| Disk Enclosure Configurations |
Dual IOM3 (Input/Output Module) Controller modules |
| Power Supply/Cooling Fans |
Dual (SATA) or quadruple (SAS), redundant, hot-pluggable, integrated power supply/fan assemblies 8 |
| Operating Temperature Range |
41°F to 104°F - (5°C to 40°C) |
| Nonoperating Temperature Range |
34°F to 122°F - (1°C to 50°C) |
| Relative Humidity |
20 to 80% noncondensing |
| Operating Acoustic Noise |
6.6B LwA @ 20°C |
| Input power frequency, Hz (AC) |
50 to 60 |
| Dimensions (height/width/depth) |
4 EIA U (7", 17.8 cm)/19” IEC rack-compliant (19", 48.3 cm)/24" (61 cm) |
| Clearance Dimensions (front-cooling/rear-cooling and maintenance/front-maintenance) |
6” (15.3cm)/12” (30.5cm)/25” (55.9cm) |
| Weight |
110 lb (49.9 kg) fully loaded, 53.7 lbs (24.4 kb) without disk drives |
|
| |
| Vendor |
Model |
| Brocade |
Silkworm 2400/2800 (TapeSAN only)
|
| Brocade |
Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/5000/48000
|
| McData |
ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
|
| Cisco |
MDS 9120/9140/9216/9506/9509/9513/9020/9124/9222i/9134
|
| Qlogic |
5600/5602
|
|
| |
| Includes 2 Sets of Dual 16A, Zero U Power Distribution Units (PDUs) or
1 Set of 24A Zero U PDUs |
Accommodates 1 controller and 12 disk shelves or 2 controllers and 10 disk shelves or 14 disk shelves
1 controller and 10 disk shelves or 2 controllers and 6-8 disk shelves or 11-14 disk shelves only |
| AC Power |
200 to 240VAC |
| Current |
32A total-2 redundant sets of dual 16A cables with NEMA L6-20 or IEC 309 connectors or Australia AS/NZ53123-20; 24A total-2 redundant cables with NEMA L6-30 or IEC 309 connectors |
| Dimensions (height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
| Min. Clearances |
48" (122 cm) front and rear |
| Shipping Height |
90.6" (230 cm) |
| Weight (empty) |
275 lb (125 kg) |
|
| |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI |
|