NetApp FAS6000 Series Technical Specifications

A new version of this product is available.
Please see the FAS6200 page.

View specifications for:
Product Highlights

Operating System

NetApp Data ONTAP® 7.2.4 or later software

Operating Systems Supported

Windows® 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware, ESX

Standard Software Features

Integrated automatic RAID manager, including RAID-DP™, Snapshot™, Fast Boot, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, FlexVol®, FlexShare™, SSH, Maintenance Center, Network Data Management Protocol (NDMP)

File Service and Other Protocol Support

NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts

SAN Protocol Support

Fibre Channel Protocol (FCP) (8/4/2/1Gb); fabric-attached and direct-attached; IP SAN (iSCSI), Fibre Channel over Ethernet (FCoE)

Licensed Software Products

FlexClone™, FlexCache, MultiStore®, SnapMirror®, SnapRestore®, SnapDrive®, SnapManager® for Microsoft Exchange, SnapManager for Microsoft SQL Server, SnapManager for Oracle®, Single Mailbox Recovery, SnapVault®, SnapMover®, SnapLock® Compliance, SnapLock Enterprise, SyncMirror®, MetroCluster, CommandCentral™ Storage, Protection Manager2 ,File Storage Resource Manager, SAN Manager, Operations Manager3, ApplianceWatch™ for HP Openview, ApplianceWatch for Tivoli®

Standard Hardware Features

ROHS-compliant, full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote LAN Management (RLM) Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220 V 42U 19" system cabinet

Maximum RAID Group Sizes

RAID 6 (RAID-DP) FC – 28 (26 data disks plus 2 parity disks), SATA – 16 (14 data disks plus 2 parity disks)
RAID 44 FC – 14 (13 data disks plus 1 parity disk), SATA – 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)

Supported Configurations Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA600

Disk Shelves Supported (Fibre Channel, SATA) and Configurations

DS14, DS14mk2 FC, DS14mk4 FC, DS14mk2AT
Dual-path
DS4243, MPHA (MultiPath High Availability)

Disk Drive Capacities Supported

FC-91/181/361/721/300GB, 450GB, 600GB
SATA-500GB, 1TB, 2TB
SAS: 300GB, 450GB, 600GB

1 9/18/36/72GB drives are supported but not currently shipping.
2 Protection Manager was previously known as Business Continuance Option.
3 Operations Manager was previously known as DataFabric® Manager (DFM).
4 RAID 6 is the recommended configuration for drives greater than 144GB.
 
System Specifications
FAS6080
FAS6040
  Active/Active Configuration Single Controller Active/Active Configuration Single Controller
Max. Raw Capacity (5), (6)

2,352TB

2,352TB

1680TB

1680TB

Max. Number of Disk Drives

1,176

1,176

840

840

Max. Number of FC Loops (dual attach)

14

14

10

10

Max. Drives per FC Loop 84
Max. Volume/Aggregate Size 16TB
Max. Number of LUNs per Controller 2048
ECC Memory

64GB

32GB

32GB

16GB

Nonvolatile Memory

4GB

2GB

1GB

512MB

Onboard GbE Ports

12

6

12

6

Onboard 4Gb FC Ports (target or initiator)7

16

8

16

8

5 Max. capacity is derived based on the type, size, and number of the drives.
6 Max. capacity is calculated using Base10 arithmetic (i.e., 1TB = 1,000,000,000,000 bytes).
7 Autosensing ports: 1, 2, 4Gb.
 
I/O Expandability
FAS6080
FAS6040
  Active/Active
Configuration
Single
Controller
Active/Active
Configuration
Single
Controller
PCI Express Expansion Slots 10 5 10 5
PCI-X Expansion Slots 6 3 6 3
Optional Network Connectivity (max.)
 Quad GbE TOE (copper) Cards
 Quad GbE (copper) Cards
 Single 10GbE TOE (fiber) 10GBASE-SR Cards
 Dual 10GbE TOE (fiber) 10GBASE-SR Cards
 Dual GbE (copper or fiber) Cards
 Dual iSCSI (copper or fiber) Adapters

10
10
4

10

10
6

5
5
2

5

5
3

10
10
4

10

10
6

5
5
2

5

5
3

Dual 4Gb FC Initiator Adapters (max.)

10

5

10

5

Quad 4Gb FC Initiator Adapters (max.)

10

5

10

5

Dual 4Gb FC Target (SAN) Adapters (max.)

8

4

8

4

Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)1

8

4

8

4

Dual FC, LVD SCSI Tape Adapters (max.)

6

3

6

3

4port SAS HBA

 

 

 

 

Performance Acceleration Module (PAM)

10

5

8

4

512GB Flash Cache1
(max cards)

8

4

4

2


1Requires Data ONTAP 7.3.2 or later, 8.0.1 or later
 
System Environmental
Specifications
Active/Active
Configuration
Single Controller Configuration
AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only) 100 to 120VAC, 11.2A (typical)
200 to 240VAC, 5.8A (typical)
19.4A (max.) @ 100VAC
9.6A (max.) @ 200VAC
100 to 120VAC, 5.6A (typical)
200 to 240VAC, 2.9A (typical)
9.7A (max.) @ 100VAC
4.8A (max.) @ 200VAC
Thermal Rating 3740 Btu/hr, 1096W (typical) 1870 Btu/hr, 548W (typical)
Weight 242 lb (109.6 kg) 121 lb (54.8 kg)
Height 20.8" (52.8 cm), fits into 12U space 10.3" (26.2 cm), fits into 6U space
Width 19" IEC rack-compliant (17.53", 44.53 cm)
Depth 23.5" (59.7 cm), 29.05" (73.8 cm) with cable management bracket
Operating Temperature, Altitude, and Relative Humidity 10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating Temperature and Relative Humidity -40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise 56.5 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Min. Cabinet Clearances 1.85" (4.7 cm) for bezel, 3" (7.6 cm) for cable radius
Min. Service Clearances 25" (63.5 cm) from front of cabinet; 40" (76 cm) from rear of cabinet
 
DS14 Disk Drive Storage Expansion Shelf Specifications
Disk Drive Storage Shelf DiskShelf14 family—DS14, DS14mk4 FC, and DS14mk2AT; each w/14 low-profile slots for FC and SATA disk drives
Disk Drive Storage Shelf Interface PCI-based Fibre Channel-Arbitrated Loop (FC-AL)
DiskShelf14 Interface Dual, redundant electronically switched hub (ESH4) modules or dual, redundant ATA modules
Power Supply/Cooling Fans Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)
AC Power/Max. Current 100 to 120VAC/4.52A; 200 to 240VAC/2.23A
Thermal Rating 1,538 Btu/hr (fully loaded shelf)
Operating Acoustic Noise 49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Dimensions (height/width/depth) 3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
Weight 77 lb (35 kg) fully loaded
 
DS4243 Disk Drive Storage Expansion Shelf Specifications
Disk Drive Types and Capacities Supported SAS 15,000 RPM: 300GB, 450GB, 600GB
SATA 7,200 RPM: 500GB, 1TB, 2 TB
All shelves have 24 bays for 3.5” low-profile SAS or SATA disk drives
Disk Enclosure to Controller Interface Serial Attached SCSI (SAS) operating at 3Gb, requires PCIe SAS Host Bus Adapter card or available embedded SAS port
Disk Enclosure Configurations Dual IOM3 (Input/Output Module) Controller modules
Power Supply/Cooling Fans Dual (SATA) or quadruple (SAS), redundant, hot-pluggable, integrated power supply/fan assemblies
Operating Temperature Range 41°F to 104°F - (5°C to 40°C)
Nonoperating Temperature Range 34°F to 122°F - (1°C to 50°C)
Relative Humidity 20 to 80% noncondensing
Operating Acoustic Noise 6.6B LwA @ 20°C
Input power frequency, Hz (AC) 50 to 60
Dimensions (height/width/depth) 4 EIA U (7”, 17.8 cm)/19” IEC rack-compliant (19”, 48.3 cm)/24” (61 cm)
Clearance Dimensions (front-cooling/rear-cooling and maintenance/front-maintenance) 6” (15.3cm)/12” (30.5cm)/25” (55.9cm)
Weight 110 lb (49.9 kg) fully loaded, 53.7 lbs (24.4 kb) without disk drives
 
FC = Fibre Channel; LVD = Low Voltage Differential.
 
NetApp Systems Cabinet
Includes 2 Sets of Dual 16A, Zero U Power Distribution Units (PDUs) or 1 Set of 24A Zero U PDUs Accommodates 1 controller and 12 disk shelves or 2 controllers and 10 disk shelves or 14 disk shelves
1 controller and 10 disk shelves or 2 controllers and 6-8 disk shelves or 11-14 disk shelves only
AC Power 200 to 240VAC
Current 32A total-2 redundant sets of dual 16A cables with NEMA L6-20 or IEC 309 connectors or Australia AS/NZ53123-20; 24A total-2 redundant cables with NEMA L6-30 or IEC 309 connectors
Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
Min. Clearances 48" (122 cm) front and rear
Shipping Height 90.6" (230 cm)
Weight (empty) 275 lb (125 kg)
 
Regulations NetApp FAS6000 Series Storage System, DiskShelf14
Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI
FC and FCoE Switch Support
NetApp offers broad support for FC and FCoE switches. A list of switches available through NetApp can be found here. For the complete list of supported switches, please consult the interoperability matrix found on the NetApp support site. Login access is required.