  FAS3270 with Expanded I/O FAS3270 FAS3240 with Expanded I/O FAS3240 FAS3210
Maximum System Capacity 2,880TB 2,880TB 1,800TB 1,800TB 720TB
Maximum Drives 960 960 600 600 240
Controller Form Factor Dual enclosure HA; 2 controllers in two 3U chassis, total of 6U Single enclosure HA; 2 controllers in single 3U chassis Dual enclosure HA; 2 controllers in two 3U chassis, total of 6U Single enclosure HA; 2 controllers in single 3U chassis Single enclosure HA; 2 controllers in single 3U chassis
Memory 40GB 40GB 16GB 16GB 8GB
Maximum Flash Cache 2TB 2TB 1TB 1TB 512GB
PCIe Expansion Slots 12 4 12 4 4
Onboard I/O: 4Gb FC 4 4 4 4 4
Onboard I/O: 6Gb SAS 4 4 4 4 4
Onboard I/O: GbE 4 4 4 4 4
Storage Networking Supported FC; FCoE; IP SAN (iSCSI); NFS; CIFS; HTTP; FTP
OS Version Data ONTAP® 7 and 8
High-Availability Features Alternate Control Path (ACP);
Ethernet-based service processor and Data ONTAP management interface;
redundant hot-swappable controllers, cooling fans, power supplies, and optics
Supported Configurations Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA320
Software Features
Standard
One SAN or NAS protocol (iSCSI, FC, NFS, or CIFS)
RAID manager, including RAID-DP®
Snapshot
FlexVol®
FlexShare®
Deduplication
Compression (check with sales representative for ordering instructions)
Thin provisioning
Disk sanitization
Operations Manager
Provisioning Manager
Protection Manager
Protection Manager DR
DFM Management Server (optional)
System Manager
FilerView®
MultiStore®
FlexCache
Cluster failover
MetroCluster
SyncMirror®
Open Systems SnapVault
DSM/MPIO
Optional
Extended Value software:
Additional SAN/NAS protocols (iSCSI, FC, NFS, CIFS)
SnapRestore®
SnapMirror®
SnapVault®
FlexClone®
SnapManager® Suite, includes:
SnapManager for Microsoft® Exchange,
SnapManager for Microsoft SQL Server®,
SnapManager for Oracle®,
SnapManager for Microsoft SharePoint® Server,
SnapManager for SAP®,
SnapManager for Hyper-V™,
SnapDrive® for UNIX®,
SnapDrive for Windows®
NetApp Complete Bundle (includes all above Extended Value software)

Other software:
SnapLock® Compliance
SnapLock Enterprise
Disk Shelves Supported DS2246 (2U; 24 drives, 2.5” SAS SFF 10K RPM 450GB/600GB)
DS4243 (4U; 24 drives, 3.5” SATA 7.2K RPM 1TB/2TB/3TB; 3.5" SAS 15k RPM, 450GB/600GB; 3.5” SSD 100GB) (Note: 3TB drive requires Data ONTAP 8; SSDs not currently supported with FAS3210)
DS14mk2 and DS14mk4 (3U; 14 drives, 3.5” FC 450GB/600GB, 3.5” SATA 1TB/2TB)
Maximum RAID Group Sizes RAID 6 (RAID-DP)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 20 (18 data disks plus 2 parity disks)

RAID 4
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)
Operating Systems Supported Windows 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun Solaris, AIX, HP-UX, Mac® OS, VMware®, ESX
Maximum Number of LUNs 4,096
Number of Supported SAN Hosts Up to 512 hosts per HA pair
Up to 24 directly connected servers per HA pair
FlexVol® Volumes Up to 500 per controller
Snapshot Copies Up to 127,000
Maximum Volume/Aggregate Size 70TB 70TB 50TB 50TB 50TB
Maximum port count includes integrated ports and PCIe expansion slots
FC Target (8Gb/4Gb) (max.) 24/52 8/20 24/52 8/20 8/20
10GbE/FCoE Target Ports (max) 24 8 24 8 8
GbE (max.) 52[1] 20 52[1] 20 20
6Gb SAS (max.) 52 20 52 20 20
FC Initiator (max.) 52 20 52 20 20
Maximum Adapters
Dual 10GbE (optical or copper) 12 4 12 4 4
Quad GbE (copper) 12[1] 4 12[1] 4 4
Dual 10GbE FCoE SAN Unified Target Adapter (optical or copper) 12 4 12 4 4
8Gb FC Target (optical) 12 4 12 4 4
Dual 8Gb VI for SnapMirror® over Fibre Channel (SMoFC) 2 2 2 2 2
Flash Cache Performance Acceleration Module (1TB) 2 2 N/A N/A N/A
Flash Cache Performance Acceleration Module (512GB) 4 4 2 2 N/A
Flash Cache Performance Acceleration Module (256GB) N/A N/A 4 4 2[2]
Quad 6Gb SAS Storage HBA 12 4 12 4 4
Quad 4Gb FC Storage/Tape HBA 12 4 12 4 4
Dual SCSI Tape HBA 12 4 12 4 4

[1] Maximum number of Ethernet ports on all network adapter cards depends on the Data ONTAP release in use
[2]Flash Cache is not supported with Data ONTAP 8.1 running on the FAS/V3210 systems

System Environmental Specifications
Thermal Rating 1,884 BTU (typical) 2,485 BTU (worst case) 1,393 BTU (typical) 1,867 BTU (worst case) 1,591 BTU (typical) 2,168 BTU (worst case) 1,256 BTU (typical) 1,707 BTU (worst case) 1,577 BTU (typical) 2,137 BTU (worst case)
Weight 148 lb 80 lb 148 lb 80 lb 80 lb
Height 10.2” (26 cm), fits into 6U space 5.1” (13 cm), fits into 3U space 10.2” (26 cm), fits into 6U space 5.1” (13 cm), fits into 3U space 5.1” (13 cm), fits into 3U space
Width 19" IEC rack-compliant (17.6”, 44.7 cm)
Depth 24” (26.5” w/cable management)
Operating Temperature, Altitude, and Relative Humidity 10° C to 40° C (50° F to 104° F); at <= 3,000 m (at <= 10,000' feet) elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
Nonoperating Temperature and Relative Humidity -40° C to 65° C (-40° F to 149° F); 5% to 95% relative humidity, noncondensing, in original container
Operating Acoustic Noise ≤ 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
Compliance RoHS-compliant
Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI


NetApp Systems Cabinet
Rack Space 42U
Dimensions (height/width/depth) 78.75" (200 cm)/23.6" (60 cm)/44.3" (112.5 cm)
Minimum Cabinet Clearances for Airflow 10" (25.4 cm) front and 12” (30.5 cm) rear
Minimum Cabinet Clearances for Service 30” (76.3 cm) front and rear, 12” top
AC Power 200 to 240VAC
Current 30A Single Phase or 3-Phase
Weight (empty) 307 lbs (138 kg)
Features Split rear door with cable egress opening Reversible front door (left- or right-handed)


Regulations FAS3200 Series Storage System
Safety/Emissions/Immunity Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI, SONCAP, NRCS LOA (South Africa)

Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, KCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, SABS COC (South Africa), BSMI


FC and FCoE Switch Support