| Maximum RAID Group Sizes |
RAID-DP® (high performance RAID 6)
FC: 28 (26 data disks plus 2 parity disks)
SATA: 16 (14 data disks plus 2 parity disks)
RAID 41
FC: 14 (13 data disks plus 1 parity disk)
SATA: 7 (6 data disks plus 1 parity disk)
RAID 0 (striping over third-party Array LUNs)2
SyncMirror® (high resiliency RAID 1)
Options:
- RAID-DP + RAID 1
- RAID 4 + RAID 1
|
| SAN Protocol Support |
Fibre Channel Protocol (FCP) for SCSI (4/2Gb); fabric-attached and direct-attached; IP SAN(iSCSI), Fibre Channel over Ethernet (FCoE) |
| File Service Protocol Support |
NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS |
| Other Protocol Support |
HTTP 1.0, HTTP 1.1 virtual hosts |
| LUNs |
Up to 2,048 server host LUNs |
| FlexVol® Volumes |
Up to 500 per controller |
| Volume/Aggregate Size 3 |
16TB |
| Snapshot™ Copies |
Up to 127,000 |
| Number of Supported SAN Hosts |
Up to 12 ports4 per controller configured as front-end (host) connectivity ports
Up to 12 directly connected servers5 (per controller and per active-active configuration)
Up to 256 SAN connected servers (per controller and per active-active configuration) |
| Supported Configurations |
Highly Available Controller Configurations
Active-active controller with controller failover6, active-active controller with stretch (non switch) MetroCluster, active-active controller with fabric-attached MetroCluster
Highly Available Back-End (Disk) Configurations
Dual-path, multipath HA storage |
| Reliability |
Redundant hot-swappable controllers, cooling fans, power supplies, optics, and RJ-45 ports |
| Management |
Onboard serial console, diagnostic LED, full-duplex 10/100Base-T Ethernet remote LAN management port with RLM and onboard management interfaces, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts |
| Security |
Virus Protection
Authentication: Kerberos (MIT/Active Directory)
Authorization: LDAP, NIS
Auditing: File access logging
Encryption: IPSec, SSL, SSH, SMB signing
Role-Based Access Control (RBAC) |
| Disk Shelves Supported (Fibre Channel, SATA) and Configurations |
DS14mk2 FC, DS14mk4 FC, DS14mk2AT
DS4243, Dual-path,MPHA (MultiPath High Availability) |
| Disk Drive Capacities Supported |
FC—91/181/361/721/144/300/450GB, 600GB
SATA—2501GB, 3201GB, 500GB, 750GB, 1TB, 2TB
SAS - 300GB, 450GB, 600GB |
|
| |
| |
Active-Active
Configuration |
Single Controller |
Active-Active
Configuration |
Single Controller |
Active-Active
Configuration |
Single Controller |
| Maximum Number of Disk Drives6 |
840 |
840 |
672 |
672 |
420 |
420 |
| V-Series Array LUNs7 |
840 |
840 |
672 |
672 |
420 |
420 |
| Maximum Drives per Back-End (Disk) FC Loop |
84 |
84 |
84 |
84 |
84 |
84 |
| Memory (ECC) |
32GB |
16GB |
16GB |
8GB |
8GB |
4GB |
| Non volatile Memory |
4GB |
2GB |
4GB |
2GB |
1GB |
512MB |
|
| |
| |
Active-Active
Configuration |
Single Controller |
Active-Active
Configuration |
Single Controller |
Active-Active
Configuration |
Single Controller |
Fibre Channel Ports
(target or initiator) |
8 ports
1, 2, or 4Gb
(auto-sensing) |
4 ports
1, 2, or 4Gb
(auto-sensing) |
8 ports
1, 2, or 4Gb
(auto-sensing) |
4 ports
1, 2, or 4Gb
(auto-sensing) |
8 ports
1, 2, or 4Gb
(auto-sensing) |
4 ports
1, 2, or 4Gb
(auto-sensing) |
| GbE Ports |
4 |
2 |
4 |
2 |
4 |
2 |
| I/O Expansion Slots |
8 |
4 |
8 |
4 |
8 |
4 |
|
| |
| |
| |
Active-Active
Configuration |
Single Controller |
Active-Active
Configuration |
Single Controller |
Active-Active
Configuration |
Single Controller |
| 2-Port FC Disk Adapters (max.) |
8 |
4 |
8 |
4 |
8 |
4 |
| 2-Port 4Gb FC Target Adapters (max.) |
4 |
2 |
4 |
2 |
4 |
2 |
| 4-Port 4Gb FC Disk/Tape HBAs (max.) |
8 |
4 |
8 |
4 |
8 |
4 |
| 4-Port 4Gb FC Target Adapter (max.)
8 |
6 |
3 |
6 |
3 |
6 |
3 |
| 2-Port Ultra320 SCSI Tape HBA |
8 |
4 |
8 |
4 |
8 |
4 |
Optional Network/SAN Cards (max.)
2-Port FC Tape Adapters
4-Port 1GbE (copper) Cards
4-Port 1GbE TOE (copper) Cards
2-Port 10GbE TOE (fiber) Cards
2-Port 1GbE (copper or fiber) Cards
2-Port 1Gb iSCSI (copper or fiber) HBA |
8
8
8
8
8
8 |
4
4
4
4
4
4
|
8
8
8
8
8
8 |
4
4
4
4
4
4
|
8
8
8
8
8
8 |
4
4
4
4
4
4 |
| Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)9 |
8 |
4 |
8 |
4 |
8 |
4 |
Performance Acceleration Module
(max cards) |
8 |
4 |
8 |
4 |
4 |
2 |
256GB Flash Cache1
(max cards) |
|
|
4 |
2 |
2 |
1 |
512GB Flash Cache1
(max cards) |
4 |
2 |
|
|
|
|
1Requires Data ONTAP 7.3.2 or later, 8.0.1 or later
|
| |
| Storage Interface/Data Rate |
PCI-Based Fibre Channel Fabric and Fibre Channel-Arbitrated Loop (FC-AL)/1 to 4Gb/sec |
| Storage Arrays |
IBM
Enterprise Storage Server (ESS), DS 4000 storage
HDS
USP Platform, AMS, Lightning Series, Thunder Series, SANRISE Series (Japan Only)
HP
StorageWorks XP Arrays, StorageWorks Enterprise Virtual Arrays
EMC
Symmetrix, Clariion
Fujitsu
ETERNUS Platform
3PAR
InServ Family
SUN
StorageTek
|
|
| |
| Vendor |
Model |
| Brocade |
Silkworm 48000, 24000, 12000, 7500, 5000, 4900 4100, 4020, 4012, 3900,3850, 3800, 3250, 3200, 3016, 3014, 2800, 200E |
| Cisco |
MDS 9513, 9509, 9506, 9216, 9216A, 9216i, 9140, 9124, 9120, 9020 |
| McDATA |
Sphereon 4700, 4500, 4400, 4300
Intrepid 6140, 6064 |
|
| |
| Operating System |
NetApp Data ONTAP |
| Host Operating Systems Supported |
Windows® 2000, Windows Server 2003, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware®, ESX |
| Software Features |
Standard
RAID manager, including RAID-DP
Snapshot
Fast Boot
NIS
DNS
FilerView®
FlexVol
FlexShare™
Deduplication
Network Data Management Protocol (NDMP)
Maintenance Center
|
Licensed
11
FlexClone®
FlexCache™
MultiStore®
SyncMirror
Protection Software
SnapMirror®
SnapRestore®
SnapVault®
Open Systems SnapVault
SnapLock® Compliance
SnapLock Enterprise
MetroCluster
Management Software
SnapManager® for Microsoft Exchange
SnapManager for Microsoft SQL Server™
SnapManager for Oracle
SnapManager for Microsoft SharePoint® Server
SnapManager for SAP®
SnapManager for Virtual Infrastructure
SnapValidator for Oracle
ApplianceWatch™
SnapDrive® for UNIX®
SnapDrive for Windows
Protection Manager
CommandCentral™ Storage
File Storage Resource Manager
Operations Manager
Provisioning Manager
Single Mailbox Recovery |
|
| |
Storage Expansion Shelves Supported
(Fibre Channel, SATA) |
FC: DS14mk4 FC
DS14mk2 FC
SATA: DS14mk2 AT
All shelves have 14 bays for 3.5” low-profile FC or SATA disk drives |
| Storage Expansion Shelf to Controller Interface |
Fibre Channel-Arbitrated Loop (FC-AL) |
| Storage Expansion Shelf Configurations |
New System Configurations
FC: DS14mk4 FC with ESH4 (Embedded Switched Hub 4) Electronics
SATA: DS14mk2 AT with AT-FCX Electronics
Supported via Upgrade Migrations from Installed Systems
FC: DS14mk4 FC with ESH4 Electronics
DS14mk2 FC with ESH4 or ESH2 Electronics
SATA: DS14mk2 AT with AT-FCX Electronics |
| Power Supply/Cooling Fans |
Dual, redundant, hot-pluggable, integrated power supply/fan assemblies9 |
| AC Power/Maximum Current10 |
SATA: 7200 RPM drives: 3.01/1.51/7.4A @ 100VAC/200VAC/-40VDC
FC: 10,000 RPM drives: 3.09/1.56/7.61A @ 100VAC/200VAC/-40VDC
FC: 15,000 RPM drives: 3.96/1.94/10.22ª @ 100VAC/200VAC/-40VDC |
| Thermal Rating11 |
SATA: 7200 RPM drives: 1017 BTU/hr
FC: 10,000 RPM drives: 1043 BTU//hr
FC: 15,000 RPM drives: 1394 BTU/hr |
| Operating Acoustic Noise |
49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Dimensions (height/width/depth) |
3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm) |
| Weight |
77 lb (35 kg) fully loaded |
|
| |
| Vendor |
Model |
| Brocade |
Silkworm 2400/2800 (TapeSAN only) |
| Brocade |
Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E/48000 |
| McData |
ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700 |
| Qlogic |
5600/5602 |
| Cisco |
MDS 9120/9140/9216/9506/9509/9513/9124 |
|
|
|
| |
20A and 30A single-phase cabinets
20A Cabinet: Includes 4 power cords with NEMA L6-20 or IEC 309 or Australia AS/NZ53123-20 connectors
30A Cabinet: Includes 4 power cords with NEMA L6-30P or IEC 309 |
20A Cabinet: 1 FAS3100 chassis & 12 DS14-type shelves
30A Cabinet: 1 FAS3100 chassis & 12 DS-14 type shelves |
| AC Power |
200 to 240VAC |
| Current |
20A Cabinet: Maximum 32A total
30A Cabinet: Maximum 24A total |
| Dimensions (height/width/depth) |
78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm) |
| Min. Clearances |
48" (122 cm) front and rear |
| Shipping Height |
90.6" (230 cm) |
| Weight (empty) |
275 lb (125 kg) |
|
| |
| Controller Weight |
122 lb (55.3 kg) |
95 lb (43.1 kg) |
| Controller Height |
10.2" (26 cm), fits into 6U space |
10.24" (26 cm), fits into 6U space |
| Controller Width |
19" IEC rack-compliant (17.6", 44.7 cm) |
| Controller Depth |
24.3" (61.7 cm), 28" (71.1 cm) with cable management bracket |
| Operating Temperature, Altitude, and Relative Humidity |
10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000' feet) elevation; 20% to 80% relative humidity, non-condensing (28° C wet bulb temperature) |
| Non operating Temperature and Relative Humidity |
-40° C to 70° C (-40° F to 158° F); 5% to 95% relative humidity, non-condensing, in original container |
| Operating Acoustic Noise |
= 61 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level) |
| Min. Cabinet Clearances for Airflow |
10" (25.4 cm) in front, 12" (30.5 cm) in rear |
| Min. Cabinet Clearances for Service |
30" (76.2 cm ) in front, 30" (76.2 cm) in rear |
| Compliance |
RoHS-compliant |
| Safety/Emissions/Immunity |
Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, BCC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3 |
|
| |
| Model |
Input Voltage |
|
Active/Active |
Single Controller |
| Typical |
Maximum |
Typical |
Maximum |
One
Side |
Both
Sides |
One
Side |
Both
Sides |
| V3140 |
100-120VAC |
Current, A |
2.99 |
5.97 |
7.38 |
1.89 |
3.77 |
3.98 |
| Power, W |
297 |
594 |
736 |
187 |
373 |
396 |
| Thermal, BTU/hr |
1013 |
2026 |
2509 |
636 |
1272 |
1350 |
| 200-240VAC |
Current, A |
1.49 |
2.98 |
3.6 |
0.97 |
1.93 |
1.97 |
| Power, W |
291 |
581 |
712 |
183 |
366 |
385 |
Thermal,
BTU/hr |
991 |
1981 |
2427 |
625 |
1249 |
1313 |
| V3160 |
100-120VAC |
Current, A |
4.07 |
8.14 |
9.74 |
2.37 |
4.74 |
5.07 |
| Power, W |
405 |
810 |
969 |
235 |
470 |
505 |
| Thermal, BTU/hr |
1381 |
2761 |
3305 |
801 |
1602 |
1722 |
| 200-240VAC |
Current, A |
2.02 |
4.03 |
4.69 |
1.19 |
2.38 |
2.52 |
| Power, W |
394 |
788 |
930 |
230 |
459 |
493 |
Thermal,
BTU/hr |
1343 |
2686 |
3170 |
782 |
1564 |
1680 |
| V3170 |
100-120VAC |
Current, A |
4.07 |
8.14 |
9.74 |
2.37 |
4.74 |
5.07 |
| Power, W |
405 |
810 |
969 |
235 |
470 |
505 |
Thermal,
BTU/hr |
1381 |
2761 |
3305 |
801 |
1602 |
1722 |
| 200-240VAC |
Current, A |
2.02 |
4.03 |
4.69 |
1.19 |
2.38 |
2.52 |
| Power, W |
394 |
788 |
930 |
230 |
459 |
493 |
Thermal,
BTU/hr |
1343 |
2686 |
3170 |
782 |
1564 |
1680 |
|